241 reported freezes, lockouts, dead network ports and lost settings on Blackmagic ATEM switchers, each with its source. Search them by model and firmware, and add what happened to yours.

What the reports have in common

Most reports are from users in public forum threads; few name a confirmed cause. On the large switchers the usual shape is the same: control and status freeze first, video keeps passing through, and a power cycle is usually the only way back. These patterns stand out.

Constellation HD: control locks up while video keeps running

From 2023 to 2025, owners of 2 and 4 M/E Constellation HD switchers report that control stops while the switcher stays on. Source buttons and Cut/Auto stop responding, panels, tally and ATEM Software Control lose their connection, and program video often keeps running. Where ping was tested, the switcher still answered it. A power cycle is the usual way out. The maintainer of the atem-connection library wrote that the problem “only seems to be happening with the Constellation HD models”.

Constellation 4K: the Ethernet port goes dead

Reports on firmware from 9.6.2 to 10.2.1 describe the network port stopping completely: no ping and no traffic, while control over USB still works. Restarts and replugging help only sometimes. One user says a downgrade restored stability; another says 10.3 seemed to solve it, while still testing.

Constellation 8K: front-panel buttons freeze

Owners of two units report that the hardware buttons freeze after the intercom buttons are pressed, still on 9.5.1 and 9.6.2. Earlier reports from 2020 and 2022 describe a cascade: panels and computers drop off, then the front buttons stop, while video keeps running. In a 2025 Reddit thread an owner describes about 10 lockups in two years, across firmware versions up to 9.6.3: network control lost, ping and ATEM Setup over USB still working, front-panel buttons dead except the Settings menu. A regular in the thread called it a common issue that has improved with later updates, and advised putting the switcher on its own subnet, or its own VLAN.

Television Studio HD: labels and startup state are not kept

From firmware 8.2.1 on, owners report labels, media and startup state lost after a power cycle, on several units and versions up to 8.11. Posts in the same threads relay Blackmagic support recommending 7.5.2 for working media and startup state, and, in 2026, calling 7.5.2 the last version with full support.

Many clients, fast reconnects and network floods

The trigger named most often is the number of connected clients and how often they reconnect. Every panel, ATEM Software Control, Companion, tally and HyperDeck takes a session; the reports name no official limit, and community figures run from about 5 to about 8. One 4 M/E Constellation HD refused new clients at about nine. Clients that acknowledge late make the switcher resend its whole backlog. Replies in one Reddit thread name MIDI over the network, which ATEM Software Control passes to the switcher, as a possible cause of lockups; the software has a setting to turn it off. A first-hand report says bursts of mDNS lock up network control on newer models with black front panels until a reboot. Heat is often suspected and has not been shown to be the cause in these reports.

ATEM Micro Panel on 10.2 and 10.2.1: the panel goes blank

From January 2026, about ten users on Reddit report that the Micro Panel goes blank and stops responding every few minutes to tens of minutes after updating to 10.2 or 10.2.1, with Constellation HD and Constellation 4K switchers. Replugging USB-C helps for a while, and downgrades often fail with “Update Failed, Check Connection”. According to the thread, Blackmagic could not make it fail; keeping the panel on its old firmware from a separate computer worked for one user.

HDMI CEC from one source can stop tally and camera control

An owner of an ATEM Mini Extreme ISO G2 found that Raspberry Pi HDMI sources on other inputs stopped tally and HDMI camera control for a Blackmagic camera, while video was fine. An inline HDMI CEC blocker on each Pi fixed it. The poster's explanation is that one CEC controller serves all HDMI inputs; Blackmagic's lab found no fault in a minimal setup, and a reply saw the same with HDMI-over-Ethernet extenders.

Before you power-cycle it

Most reports cannot tell these apart afterwards. A minute spent on them makes your report useful.

  • Is program video still moving? Are the multiview audio meters moving?
  • Do the front-panel source buttons, Cut/Auto, the menu and the knob still work?
  • Does the switcher answer ping, and its web page if it has one?
  • Which clients were connected: panels, ATEM Software Control on each computer, Companion, tally, HyperDecks?
  • Which firmware is it running? ATEM Setup over USB shows it.
  • After the restart: are labels, routing, multiview and the video mode still as they were?

Incidents

241 of 241 incidents

SymptomTrigger / contextSource
2026-11-10Constellation 8KNot statedFront panel, recording or video freezeBecame sluggish, front panel includedOne control client too many was openedCame back when that software was closed. Another user replied that this is a known issue on most Blackmagic switchersFixed or improvedFirst-hand report
2026-11-10ATEM Advanced PanelNot statedFront panel, recording or video freezePanel frozeA custom input label with a Nordic letter (æ, ø or å) was sent through CompanionPower cycle, then the same label set from ATEM Software ControlFixed or improvedFirst-hand report
2026-11-104 M/E Constellation HDNot statedControl lockoutControl engine freezes, many times over several years. Video passes through and ATEM Setup still works, but the front panel does not respond and ATEM Software Control cannot connectNot known; the owner suspects a faulty unitPower cycle. Afterwards it is sometimes fine, sometimes routing is reset and sometimes labels are back to factory defaults. Media player uploads also fail at timesCame back after recoveryFirst-hand report
2026-11-10Television Studio HDNot statedFront panel, recording or video freezeFront panel locks upFront-panel buttons pressed in quick successionNot statedNot statedFirst-hand report
2026-11-10Newer models with black front panels (ATEM switchers, Videohubs, SMPTE 2110 converters)Not statedControl lockoutNetwork control locks up until a reboot. The reporter says the symptoms could match the Constellation HD lockoutsBursts of mDNS on the network; the reporter believes bursts under 100 packets/s crashed 2110 3x3 converters. Older models with grey front panels were not affectedRebootCame back after recoveryFirst-hand report
2026-11-094 M/E Constellation HD9.6.2 or later (protocol 2.32)Control lockoutControl froze four times in two days (2026-11-09 and 10). Ping and the web page still answered; no reply to the UDP 9910 hello for any sessionTwo control clients. One freeze came while a client was acknowledging 1–4 s late and the switcher was resending heavily; one came 45 s after a power cycle with prompt acknowledgements; one with that client off the network. One host on the network sent mDNS peaks of 86–96 packets/s in the minute before two of the freezesPower cycle. After one, the mixer state was back on defaults with labels kept; after the 11-10 freeze the unit was on factory settings, labels included, and media pool uploads failedCame back after recoveryFirst-hand report
2026-10-274 M/E Constellation 4KNot statedReboot or boot hangFans run at full speed on power-up and the boot is unreliable; it needs several power cycles, then works normallyNot statedReplies: power supply voltage suspected; another 4 M/E owner says theirs always starts at full fan speed, then settles; a reflash suggestedCame back after recoveryr/VIDEOENGINEERING
2026-10-25Television Studio HD8.11 to 7.5.2Firmware update failure"Firmware update failed" after 10 min; fans at maxDowngradeOpen; needs USBUnresolvedForum t=144353
2026-10-22Television Studio HD8.11 / ATEM Software Control 11.0Settings or labels lostLabels and media graphics not kept"General", not one unitBlackmagic: 7.5.2 last version with full supportUnresolvedForum t=144353
2026-10Constellation HDNot statedClient-side faultMeters suspected frozen after re-handshakeLevel subscription is per sessionNot reproduced; re-arm each sessionUnresolvedwebatem #38PR #43
2026-09-29n/s (over VPN)Not statedClient-side faultBacklog ~180 packets (3.6 s); every packet resent 7–8 timesLibrary dropped out-of-order packets; ATEM resends its whole unacked window each frameBuffer and ack at onceFixed or improvedatem-connection PR #203
2026-09-09Mini ProNot statedFirmware update failureUSB stopped working; factory reset fails at 100%2 PCs, several cablesNo replyUnresolvedForum t=239926
2026-09-07ATEM Mini Extreme ISO G2 with Micro Studio Camera 4K G2Not statedControl lockoutVideo is fine, but tally stays dark and HDMI camera control (iris, focus, zoom) does nothingRaspberry Pi Zero HDMI sources on other inputs; it breaks the moment a Pi starts sending video. The poster's explanation: HDMI tally and camera control use CEC through one controller shared by all inputsAn inline HDMI CEC blocker (pin 13 cut) on each Pi. Blackmagic's lab found no fault in a minimal setup. A reply saw the same with HDMI-over-Ethernet extendersFixed or improvedr/blackmagicdesign
2026-08-17, 10-142 M/E Constellation HD; Constellation 8K8K: 10.2Client-side faultCompanion drops after a day or two, never recoversWorker process flagged frozenOpenUnresolvedcompanion-module #479
2026-07-28Constellation 4K10.3Ethernet dead"Seems to have solved all the problems"One user, still testingNot statedNot statedForum p=1095732
2026-06-20Not statedATEM Software Control up to 10.3 Beta 2Client-side faultATEM Software Control kept crashingMacBook Pro M1 on macOS Tahoe 26.5.1Stable only on 9.6.3Fixed or improvedr/blackmagicdesign
2026-06-02Constellation 4K10.x, then 9.5.1 (or 9.4)Ethernet deadCrash mid-event with 1 M viewersNot statedDowngrade restored stability; multiview glitches goneFixed or improvedForum p=1095732
2026-05-28ATEM SDI Extreme ISONot statedFirmware update failureAn update reached 100%, then reported failure; since then the top-left key flashes red, and reflashing every version from 8.4 to 10.2 failsAn update prompted while installing Fairlight software on a MacBlackmagic returned it unrepaired: no replacement parts availableUnresolvedr/VIDEOENGINEERING
2026-05-18Constellation 4K10.2.1Ethernet deadStill happensNot statedReplugging the network sometimes helpsCame back after recoveryForum p=1095732
2026-05ATEM Micro Panel with 1 M/E Constellation HD10.2.1 / 10.2 / 10.1 / 9.6.2Front panel, recording or video freezePanel goes blankTried on several firmware versionsA downgrade to 9.8.3 helped brieflyCame back after recoveryr/blackmagicdesign
2026-04-284 M/E Constellation HD10.2.1Client-side faultCompanion feedback lags 1–2 s after hoursLossy-network handling in the moduleModule 4.3.1Fixed or improvedcompanion-module #447
2026-03-251 M/E Constellation (several units)Not statedMedia pool or storagePower outages and reboots wipe the media pool, so a show file has to be loaded every timeDaily useThe poster's automation of the reload is inconsistentUnresolvedr/blackmagicdesign
2026-02-264 M/E Constellation 4KNot statedEthernet deadUnreachable after a few minutes on; self-assigns 169.254.1.9Static or DHCP, direct cableWorks briefly after a long unplugCame back after recoveryForum p=1095732
2026-02-182 M/E Constellation HD10.1Client-side faultClient at 30–40% CPU when idleSwitcher still sends 32 multiview commands per frameLibrary 3.9.0Fixed or improvedatem-connection #190
2026-02-08ATEM Micro Panels with two 2 M/E Constellation 4K and four Constellation HD10.2.1Front panel, recording or video freezePanels go blank on all six remote-production systemsFirmware 10.2.1Not statedUnresolvedr/blackmagicdesign
2026-01-271 M/E Advanced Panel 10 with Constellation 8K10.2Reboot or boot hangThe panel boot-loops every 12 s and never gets past "connecting", but only when pointed at the 8K; the 8K answers Companion, ATEM Software Control and ping, and the panel works with another ATEMWorked for 3 years; updated to 10.2 five weeks earlierA direct cable, static and DHCP addressing, 10.2.1 and a rollback to 9.5 did not helpUnresolvedr/VIDEOENGINEERING
2026-01-27Constellation 8K (another owner)Not statedHardware, power or heatSame panel boot loop, traced to the 8K's Ethernet controllerStarted right after a UPS was added to the metal rackThe dealer replaced the unit; the repair estimate for the board was $1600Fixed or improvedr/VIDEOENGINEERING
2026-01-13ATEM Micro Panel with 4 M/E Constellation 4K10.2Front panel, recording or video freezeThe panel goes blank and unresponsive after a while; replugging USB-C sometimes revives it for a time. ATEM Setup reads the panel inconsistentlyPanel and switcher updated to 10.2Other users: off every 5–40 minutes, or every 10 minutes or so during shows. Downgrades often fail with "Update Failed, Check Connection". Blackmagic could not make it fail. Keeping the panel on old firmware and drivers from a separate laptop worksUnresolvedr/blackmagicdesign
2025-12-052 M/E Constellation 4KNot statedEthernet deadNetwork lost after a good dayNot statedNot statedNot statedForum p=1095732
2025-12-01Mini Pro (2 units)latestSettings or labels lostStream bandwidth fields blank after power cycleRemote sitesNot statedNot statedForum t=110658
2025-11-26HD8 ISONot statedFirmware update failureATEM Setup errors over Ethernet and USBWants a factory reset, which needs SetupNot statedNot statedForum t=230636
2025-11-022 M/E Constellation HDNot statedControl lockoutMid-event it stopped responding over Ethernet and USB: still pingable and visible in ATEM Setup, but ATEM Software Control could not connect from several computersCompanion and Hollyland tally, 3 devices; two switches, no internet; another Constellation HD and a HyperDeck on the network; the software had dropped and reconnected earlier that dayEverything came back at once after a power cycle. Replies: seen twice in a couple of years; seen on busy networks; a colleague's claim of a memory leakCame back after recoveryr/blackmagicdesign
2025-10-131 M/E Constellation (HD or 4K not stated)latest thenFront panel, recording or video freezeWhen one particular Mac connects, the switcher and its program output freeze, and it cannot be controlled even from the front panel until power-cycledThat Mac: ATEM Software Control 10.0 on macOS Sequoia over a Wi-Fi router, at most the third connection; it controls other ATEM models fineA reply had the same with their ConstellationCame back after recoveryr/blackmagicdesign
2025-09-212 M/E Constellation HD10.0Front panel, recording or video freezeLockout a few minutes after every bootRestored a settings file saved on "9.7.2"Rebuilt settings by hand, no old file: fixedFixed or improvedForum t=175982
2025-08-30Mini ProATEM Software Control 9.7.1Settings or labels lostAUTO transition reverts to CUTNot statedFirmware 9.5.1 or laterFixed or improvedForum t=226593
2025-08-24ATEM Mini Pro ISONot statedSettings or labels lostChanges settings on its own, even mid-record: audio sources, and camera settings until the lens focus stops working. The startup state sometimes sticksAfter a firmware update, following about 2 years without problems; support suspected MIDI controlA replacement unit had no problems; running without ATEM Software Control was slightly more stableFixed or improvedr/blackmagicdesign
2025-08-24Television Studio HD8 ISONot statedSettings or labels lostOften goes haywire when ATEM Software Control connectsSeemed to start with a firmware updateNot statedNot statedr/blackmagicdesign
2025-08-041 M/E Production Studio 4KlatestControl lockoutDrops tied to the number of clients3 Stream Decks + ATEM Software ControlNot statedNot statedForum t=89893
2025-07-29Constellation 8K9.6.3 (and earlier versions)Control lockoutAbout 10 lockups in 2 years: network control lost (2 M/E Advanced Panel and ATEM Software Control), still answers ping and ATEM Setup over USB, front-panel buttons dead except the Settings menu, audio bars on the front screen stuckAcross different firmware versions, I/O and resolutionsA power cycle every time. A regular in the thread called it a common issue that has improved with later updates, and advised less network noise and the switcher's own L3 subnet or VLAN. Another owner had the same in 2025-10Came back after recoveryr/blackmagicdesign
2025-07-29Constellation 8K (another owner)Not statedControl lockoutSame problemNot statedThe dealer swapped the unit for a new oneFixed or improvedr/blackmagicdesign
2025-05-18Television Studio HD (1 of 2)8.1.1Settings or labels lostStopped saving startup state; twin unit fineWorked weeks beforeNo replyUnresolvedForum t=221752
2025-03-03Constellation 4KNot statedEthernet dead"Same issue"Not statedAsks about RMAUnresolvedForum p=1095732
2025-02-074 M/E Constellation (HD or 4K not stated)9.5.1Reboot or boot hangFroze completely an hour after a service; after power cycles it would not fully boot: camera 1 on every output, no display, only LOCK and MIX lit, no software controlNot statedA factory reset gave about 15 minutes; after a second factory reset and a forced update to 9.6.2 the XML loaded and it ran normally for 9 hoursFixed or improvedr/VIDEOENGINEERING
2025-01-12Not statedATEM Software Control 9.0.2Settings or labels lostNo longer saves the startup state, whatever they trymacOS Monterey 12.2Nothing workedUnresolvedr/blackmagicdesign
2024-12-27 to 2025-05-082 M/E (Constellation?) + Micro PanelATEM Software Control 9.7Client-side faultATEM Software Control + Micro Panel lock up after hours; switcher panel and Companion finePanel direct to PCRestart the appCame back after recoveryForum p=1110384
2024-12-14HD89.0.2Hardware, power or heatWhite particles on PGM and multiview; network control and tally lostLeakage current through an SDI audio de-embedderRemoving it restored tallyFixed or improvedForum p=1047304
2024-12-08ATEM Mini ExtremeNot statedReboot or boot hangRestarts on its own; sometimes boots only partway with only Mic 1 lit and needs several triesChurch use; happens without overheating (fan under it)Power cycle or restartUnresolvedr/blackmagicdesign
2024-11-28Constellation 8KNot statedFront panel, recording or video freezeAll inputs and outputs show moiréAfter many hours, 2160p50Unplug; Blackmagic contactedCame back after recoveryForum p=1102449
2024-11-062 M/E Constellation 4K (new)Not statedEthernet deadNo network, no pingNTP off didn't helpUSB only; restart didn't helpUnresolvedForum p=1095732
2024-11-06SDI Extreme ISONot statedMedia pool or storageUploads never finish; Ethernet LED lit with no cableAny formatNo answerUnresolvedForum t=211281
2024-10-31ATEM Mini Pro ISO (second-hand report)9.5.1, ATEM Software Control 9.6.2Client-side faultATEM Software Control crashes every few seconds on the Switcher, Media, Audio and Camera buttonsNot statedNot statedNot statedr/blackmagicdesign
2024-10-282 M/E ConstellationNot statedClient-side faultNeeds several connect triesPyATEMMax; session id not resetOpenUnresolvedPyATEMMax #50#43
2024-10-124 M/E Constellation 4K9.6.2Ethernet deadPort "fully blind": no ping, no panel, no trafficRandom momentsOnce USB + NTP off; next day a restartCame back after recoveryForum p=1095732
2024-10-07Advanced Panel 10 on 2 M/E Production Studio 4K9.6.2Reboot or boot hangPanel freezes, then reboots (switcher fine)Navigating right in the Settings menuBack to 9.6.1 fixed it (2 users)Fixed or improvedForum p=1089521
2024-09-302 M/E Constellation HDNot statedOutput or audio failureOutputs stop working; a reboot brings them back, sometimes for a while, sometimes only briefly. The multiview stays fairly solidIn a hot teaching-desk rackThe owner concluded the unit was broken and planned to buy a new oneUnresolvedr/VIDEOENGINEERING
2024-09-274 M/E Constellation HD9.6.2Control lockoutATEM Software Control shows "No Switcher Connected" every minute or so, back in secondsMixEffect stayed connected; no link dropLasts until power-offCame back after recoveryForum t=208261
2024-09-274 M/E Constellation HD9.6.2Firmware update failureUpdate needs "allow administration from USB and Network"That setting is USB-onlyNot statedNot statedForum t=208261
2024-09-134 M/E Constellation 4KNot statedClient-side faultNo client connects through AtemProxyProxy untested past 8.6.4OpenUnresolvedAtemProxy #5
2024-09-06Mini Extreme + ISONot statedFront panel, recording or video freezeStream and record buttons freeze; cache fillsHours of high-quality streaming + SSD; 27 °C roomUnresolvedUnresolvedForum p=990314
2024-09-052 M/E ConstellationNot statedControl lockoutHours after boot: short drops, then Companion + ATEM Software Control lostCompanion on a Pi, Wi-Fi ATEM Software Control, shared rack routerPull power; a different router fixed itFixed or improvedForum p=1078877
2024-09-05Not stated (in a Constellation 8K thread)Not statedReboot or boot hangVertical lines on the multiview, will not boot most of the time, cannot updateNot statedNot statedUnresolvedr/blackmagicdesign
2024-08-28Not statedATEM Software Control 9.6 to 9.6.2 (macOS)Client-side faultATEM Software Control crashes when the Media Player tab opens, and when the XML configuration is reloadedmacOSDowngrading the software to 9.5.1 fixed it; a second user had the same, still on 9.6.2Fixed or improvedr/blackmagicdesign
2024-08-27Production Studio 4KNot statedControl lockoutPings, but ATEM Software Control says "Not connection"First setup, direct cableNo reply; weak evidenceUnresolvedForum p=1075791
2024-08-27switcher in a 4 M/E HD threadto 9.5Firmware update failureFirmware failure halfwayNot statedRMA; Blackmagic said the Ethernet port was "shot"Not statedForum p=1096204
2024-08-264 M/E Constellation HD9.6 package (HD firmware 9.2.1)Ethernet deadNo network after update; USB-C onlyDHCP, static, direct cableLOCK-button recovery reflash with Blackmagic failed; downgrades failedUnresolvedForum p=1096204
2024-08-21Not stated (in an ATEM Mini Extreme ISO thread)Not statedFront panel, recording or video freezePhysical buttons hang about 5 minutes after the first cold power-up of the day, while software control worksFirst cold start of the day, two days runningA power cycle fixes it until the next cold startCame back after recoveryr/blackmagicdesign
2024-08-14ATEM Mini ProNot statedOutput or audio failureUSB webcam feed freezes after 5–6 minutes and the computer stops recognising the device; front-panel and software control still workStreamlabs; the same on a laptop and in the Camera appBlackmagic support said most likely a soldering issue; returnedNot statedr/VIDEOENGINEERING
2024-07-19Mini ProNot statedHardware, power or heatRuns very hot; cache fills in 2 minNot statedUser calls it "cooked"Not statedForum p=1065058
2024-07-14Not stated (in an ATEM Mini Extreme ISO thread)9.5 / 9.5.1, then 9.0.2Ethernet deadNetwork dead after the update; no DHCP lease at allFirmware update to 9.5 / 9.5.1Rolling back to 9.0.2 did not helpUnresolvedr/blackmagicdesign
2024-07-09SDI Extreme ISONot statedFront panel, recording or video freeze"Frozen in time"; buttons show last state; recording stopped6 cameras, panel, CCU, 8-source ISOPower cycle; Wi-Fi reconnect flood suspectedCame back after recoveryForum p=1062140
2024-07-09ATEM Mini Extreme ISO9.5 / 9.5.1Ethernet deadAfter the update it vanished from the network. The link LEDs are inverted: on with no cable, off with a cableFirmware update to 9.5; static and DHCP, direct and through switches, several cablesA recovery-mode reflash did not help; USB control still works. Two more owners reported the same in 2024-11 and 2025-02, USB onlyUnresolvedr/blackmagicdesign
2024-07-09ATEM SDI Extreme ISO (two of four units)9.5.xClient-side faultTwo of four updated units crash ATEM Software Control when it connects, over USB or Ethernet, on a fresh computer and after a recovery reflashFirmware update to 9.5.xSuggestions: turn off IPv6 on the network adapter; the software may crash when the switcher firmware is newer than itNot statedr/VIDEOENGINEERING
2024-06-28Not stated (in an ATEM Mini Pro thread)Not statedFront panel, recording or video freezeAbout 4 hours in, the recording counter stops with no other sign, and recording cannot be stoppedSamsung T7 and SanDisk Extreme Pro drivesPower cycle or restartCame back after recoveryr/blackmagicdesign
2024-06-24Constellation 8K9.5 to 9.6.2Front panel, recording or video freezeHardware buttons freezePressing intercom buttons; 2 unitsNot fixed in 9.5.1 or 9.6.2UnresolvedForum p=1085517
2024-06-23Mini ProNot statedFront panel, recording or video freeze"Crashed" 3 times at a weddingRecording to SSD; Streaming BridgeRestart all; mixed-up PSU or cable suspectedCame back after recoveryForum p=1065058
2024-06-21Mini Pro ISO9.5Reboot or boot hangReboots, often in a loop, with an SSD inISO recording to an approved SSDCorrect PSU fixed itFixed or improvedForum p=1057144
2024-06-02Constellation 4KNot statedControl lockoutFroze when too many control devices were connectedMany control devicesStopped after the number of devices was reducedFixed or improvedr/blackmagicdesign
2024-06-02Not stated (in a Constellation thread)Not statedControl lockoutFreezes although the number of devices is stable and under the limitNot statedBlackmagic was investigatingUnresolvedr/blackmagicdesign
2024-06-02Constellation 8KNot statedFront panel, recording or video freezeThe poster thinks pressing the PTT button for the front headset port crashes the switcherFront-panel intercom PTT buttonNot statedNot statedr/blackmagicdesign
2024-06-02ATEM Mini ExtremeNot statedFront panel, recording or video freezeButtons unresponsive for a minute mid-show, then came backNot statedRecovered by itselfCame back after recoveryr/blackmagicdesign
2024-06-02ATEM SDI Extreme ISONot statedFront panel, recording or video freezeLost recorded footageRecording to an approved Samsung T5Not statedNot statedr/blackmagicdesign
2024-06-02ATEM Mini Extreme (two units)Not statedOutput or audio failureHDMI output 2 diedNot statedNot statedNot statedr/blackmagicdesign
2024-05-16Constellation 8K9.3.3Control lockoutHyperDeck, Videohub panel, Skaarhoj links fail; discovery greyed outAfter the updateFactory reset works until next reboot; some went back to 8.6.2Came back after recoveryForum t=201543
2024-05-13HD8 ISO9.0.2Front panel, recording or video freezeButtons and fader dead; picture and meters run; ATEM Software Control has no effectFactory internal drivePower off; file lost; replacement unit same (09-25)UnresolvedForum p=1047304
2024-05-12ATEM Mini Pro and Mini Extremelatest thenControl lockoutCrashes unless the control software is not used; unplugging the Ethernet cable unfreezes it after a minute or twoATEM Software Control on PC and MacSupport emailed twice with no replyCame back after recoveryr/blackmagicdesign
2024-05-12Television Studio HDNot statedControl lockoutAt the end of a service it lost network control from ATEM Software Control and a Stream Deck. After a reboot the software saw it but could not connect, while ping worked and local buttons workedNot statedA reply had the same each time from a firmware and software version mismatchUnresolvedr/blackmagicdesign
2024-05-06ATEM SDI Extreme ISO (two units)Not statedFront panel, recording or video freezeLocking upISO recording on half the inputs, USB webcam out, 3 SDI outputsReplies: dropped Wi-Fi clients fill the connection slots and lead to lockups; another user power-cycled once with ISO recording onCame back after recoveryr/VIDEOENGINEERING
2024-05-01Mini Pro ISONot statedSettings or labels lostSettings messed upBlackmagic's reset XML for another modelNot statedNot statedForum t=156999
2024-04-121 M/E Production Studio 4K (2 units)Not statedEthernet deadNetwork settings don't persist; PC can't see itDirect or through a switchDowngrade didn't helpUnresolvedForum p=1039690
2024-04-08Mini Pro ISONot statedFront panel, recording or video freezeWhole system freezes on record; stop freezes after an updateStreaming Bridge + ISO recordPower down; can't stream and ISO-record togetherCame back after recoveryForum p=1034468
2024-03-22ATEM SDI Extreme ISONot statedFront panel, recording or video freezeRecordings failed near the end of a show: stop did not respond on the button or in software while the multiview showed them rolling. The files had frozen video and continuing audioISO recordingPower cycle or restartNot statedr/VIDEOENGINEERING
2024-03-22ATEM Mini Extreme ISONot statedOutput or audio failureThe projector output dipped several times, then went out completely while the multiview stayed fine. The unit was extremely hot5 inputs, 2 outputs through convertersNot statedNot statedr/VIDEOENGINEERING
2024-03-22ATEM SDI Extreme ISO (another owner)Not statedFront panel, recording or video freezeRecordings fail and will not stop, about three times in three yearsSamsung T7 drive implicatedA power cycle fixes it but spoils the recordings. Another owner's unit jammed on a test recordingCame back after recoveryr/VIDEOENGINEERING
2024-03-14Television Studio HD8 ISONot statedControl lockoutSeveral desk lockups; a power cycle is the only fixSeveral Wi-Fi tally lights connected to the switcherOnly one tally connects to the switcher now; the others take their state from itFixed or improvedr/blackmagicdesign
2024-03-12SDI Pro ISO9.6Front panel, recording or video freezeAfter 2–3 h: tallies stop, panel lights freeze, recording stops3 Wi-Fi tallies on busy outdoor Wi-FiEthernet tally server + better cooling: no more hangsFixed or improvedESP tally #119r/blackmagicdesign
2024-02-22ATEM Mini Extreme ISO (new)Not statedHardware, power or heatFound off and hot 20 minutes after being plugged in, and never turned on againVents clear, original power supplyNot statedUnresolvedr/blackmagicdesign
2024-02-211 M/E Production Studio 4Klatest, then 8.10Control lockoutATEM Software Control drops its connection right after connecting, while running macros still executeNot statedRolling back firmware did not helpUnresolvedr/blackmagicdesign
2024-02-194 M/E Broadcast Studio 4K9.3.2Control lockoutPanel + ATEM Software Control lose connection dailyCamera Control Panel attachedUnplug the Camera Control PanelFixed or improvedForum p=1022261
2024-02-192 M/E Constellation HD9.3.2 packageControl lockoutATEM Software Control + panel lose connection daily, for goodOld 1 M/E panel + GPI/Tally boxRestart every time; no replyUnresolvedForum p=1022261
2024-02-161 M/E Production Studio 4K (three units)Not statedControl lockoutAfter 11 months a custom switching service could no longer connect to any of the three switchers, while remote ATEM Software Control still worked; a spare switcher behaved the sameContainerised control code over a VPN; nothing changed on the networkNot statedUnresolvedr/blackmagicdesign
2024-02-15Mini8.6Client-side faultHDMI input blanks every hour (excluded: source fault)Same with Micro Converters, no ATEMNot an ATEM faultExpected or not a switcher faultForum p=1021418
2024-02-12 to 05-07HD8 ISO; Mini Pro ISONot statedFront panel, recording or video freezeRecord button freezes on 10+ min recordings; files lostInternal drive; Samsung T5Pull power; USB 3 cables fixed one userFixed or improvedForum p=1044900
2024-02-04Not stated (in a 2 M/E Constellation HD thread)Not statedFirmware update failureAfter a reboot an update stuck at 99%; then the fan ran continuously with only the LOCK button litFirmware updateNot statedUnresolvedr/blackmagicdesign
2024-01-144 M/E Constellation HD (2 units + a 2nd user)Not statedSettings or labels lostmultiview and keyer settings reset at power-up1 M/E Advanced Panel on each; "no rhyme or reason"Restore XML; no Blackmagic replyCame back after recoveryForum t=195044
2024-01-14ATEM Mini Prolatest thenOutput or audio failureFreezes mid-cut, then outputs a black image over USBThree 1080p cameras, over six monthsSometimes the OBS source also had to be removed and added againCame back after recoveryr/blackmagicdesign
2023-12-26ATEM Mini Extreme ISONot statedFront panel, recording or video freezeFroze while ISO recording to an SSDControl laptop also connected over USB-CUsing Ethernet only for control made it much more stableFixed or improvedr/VIDEOENGINEERING
2023-12-131 M/E Constellation HDNot statedMedia pool or storageAll media lost on restartVolatileRefill from a computerExpected or not a switcher faultForum t=193674
2023-12-13ATEM Mini ProNot statedFront panel, recording or video freezeRepeatedly stops recording and freezes: recording cannot be stopped or started while everything else works. Of a 2-hour podcast, 24 minutes were savedVectoTech 4 TB drive (540 MB/s), three camerasPower cycle or restartUnresolvedr/blackmagicdesign
2023-12-06ATEM Mini Pro ISOlatest thenFront panel, recording or video freezeFroze with no switching; the record stop button worked after about 10 presses. Another time it froze after about 4.5 hours of switchingOn the network with control softwareReplies: the same two weeks earlier; "happening more and more often"Came back after recoveryr/blackmagicdesignr/VIDEOENGINEERING
2023-12-06ATEM Mini ExtremeNot statedFront panel, recording or video freezeFroze the same wayHeat suspectedAdded fansFixed or improvedr/VIDEOENGINEERING
2023-11-24ATEM Mini ExtremeNot statedFront panel, recording or video freezeThe fan gets louder at random and the unit freezes, with no HDMI switchingA reply suggests overheatingUnplugging every cable and restarting, sometimes several timesCame back after recoveryr/blackmagicdesign
2023-10-12Constellation 2 M/E (HD per poster)Not statedFront panel, recording or video freezeATEM Software Control dead, multiview audio meters frozen, front panel dead; video runsCold outdoors, so not heat; generator powerReboot; "happened to me recently as well"Came back after recoveryForum p=990314
2023-10-08SDI Extreme ISONot statedFront panel, recording or video freezeApp + switcher frozen; buttons dead; program, stream, record runAll-day church stream; second time; heat suspectedReboot always worksCame back after recoveryForum p=990314
2023-09-18HD8 ISO9.0.1Front panel, recording or video freezeRecord won't stopISO, 4 cameras, internal drivePull powerCame back after recoveryForum p=1044900
2023-09-11Constellation 8K9.xControl lockoutClients drop; sometimes "hanging up the Atem"8 clients incl. 2 Companion; same rig fine on a 4 M/E on 8.xSeparate VLANFixed or improvedForum t=101841
2023-09-06ATEM Mini ProNot statedControl lockoutTwice during livestreams it stopped responding for a few minutes: the USB stream continued, but no switching from the Stream Deck, ATEM Software Control or the front panelAbout 5 connections: OBS over USB, ATEM Software Control, Companion with a Stream Deck and 3 DIY Wi-Fi tally lights, on a dedicated routerRecovered by itself both times, after which Companion and the tallies had lost the switcher. The poster suspects the connection limit; a reply had the same without tally lightsCame back after recoveryr/blackmagicdesign
2023-09-031 M/ENot statedControl lockoutAll devices drop at once, up to minutes3 PCs + panel on main LANCable swap helped for weeksFixed or improvedForum t=89893
2023-07-11Constellation 8KNot statedHardware, power or heatHot side 43 °C at ~27 °C roomNot stated"Not unusual"; leave 1U above and belowExpected or not a switcher faultForum t=184473
2023-06-264 M/E Constellation HDNot statedFront panel, recording or video freezeLockoutRight after making macros and saving a backup configPulling Ethernet didn't help; reboot didCame back after recoveryForum t=175982
2023-05-22Television Studio Pro 4KNot statedSettings or labels lostAux remap lostNever saved (user error)Save, then wait up to a minuteFixed or improvedForum t=181756
2023-05-194 M/E Constellation HDNot statedHardware, power or heatSurface 32–35 °C at 21–22 °C roomBlackmagic asked for temps; a cooled enclosure still locked upHeat not shown to be the causeNot statedForum t=175982
2023-05-09Television Studio Pro 4KNot statedFirmware update failureOnly fan and network light; all blackAfter an ATEM Setup updateNot statedNot statedForum t=181000
2023-04-23Television Studio Pro HDNot statedControl lockoutAnswers ping, but ATEM Software Control cannot connectDuplicate IP address with a PTZ joystick controllerA reply: Windows 8 compatibility mode for ATEM Software Control and ATEM Setup on Windows 11Fixed or improvedr/blackmagicdesign
2023-04-194 M/E Constellation HDNot statedHardware, power or heatControl lockoutsNot statedOwner asked for a replacementNot statedForum t=175982
2023-04 to 2024-10HD8 ISONot statedHardware, power or heatNoisy fans; bad display; multiview windows fail until rebootFrom day oneNot statedNot statedForum p=1092616
2023-03-271 M/E 4KNot statedEthernet deadLost its connection to the panel and ATEM Software Control and no longer shows on the network; video and front-panel buttons still workClassroom studioNot statedNot statedr/blackmagicdesign
2023-03-271 M/E 4K (another owner)Not statedEthernet deadThe network port failedNot statedReplaced with a 2 M/E Constellation HDFixed or improvedr/blackmagicdesign
2023-03-222 M/E + 4 M/E Constellation HDNot statedHardware, power or heatOutputs and multiview flash black; some outputs dead until power cycleExternal reference (Blackmagic, AJA sync)Distributor can't replicateUnresolvedForum t=176582
2023-03-14ATEM Mini Extreme ISONot statedFront panel, recording or video freezeFirst it answered ping but not ATEM Software Control. Later, mid-stream, the physical buttons stopped responding and showed a wrong state while the multiview, stream and software control were fineNot statedNot reproduced in a 5-hour test. A reply had the same during a big-stream install, with a frozen streamCame back after recoveryr/blackmagicdesign
2023-03-024 M/E Constellation HDbefore 9.0.1Front panel, recording or video freezeSame faultsSent to Blackmagic"Can't replicate"; a loaner 8K workedUnresolvedForum t=176582
2023-034 M/E + 2 M/E Constellation HDbefore 9.0.1Settings or labels lostWrong colour space after power cycleExternal reference in useNot statedNot statedForum t=176582
2023-02-271 M/E Production Studio 4KNot statedMedia pool or storageMedia pool reset at every power-offPower-offRestoring the saved XML brought the media back. A reply says firmware above 7.5.x breaks some features on this modelExpected or not a switcher faultr/blackmagicdesign
2023-02-134 M/E Constellation HDNot statedFront panel, recording or video freezeSource buttons and Cut/Auto dead; menu and knob work; outputs hold; panel, tally, software all dropStart of the lockout threadPower cycleCame back after recoveryForum t=175982
2023-024 M/E Constellation HDbefore 9.0.1Front panel, recording or video freezeLatency, dropped frames, random full lockup; SuperSource boxes lagNot statedBlackmagic email: 9.0.1 fixes it; some owners returned unitsNot statedForum t=176582
2023 (thread)4 M/E Constellation HDNot statedFront panel, recording or video freezeRefuses new clients at ~9; 5 devices don't last 24 h; Blackmagic's tally box makes it worsePanel, tally, ATEM Software Control, PlayDeck, CompanionFewer clients helpedFixed or improvedForum t=175982
2023 (thread)2 M/E Constellation HD (3 users)Not statedFront panel, recording or video freezeLockoutsCuebi Wi-Fi tally; Companion (weekly); tablet + ATEM Software Control (twice in 3 h)Power cycleCame back after recoveryForum t=175982
2022-12-231 M/E (15 switchers, generation not stated)Not statedControl lockoutEvery couple of days the software panels lose all 15 switchers at the same time; other devices are unaffectedOne broadcast domain with multicast video; each studio a consumer switch on its own subnet uplinked to an L3 core; static IPs, all wired, no tally or MIDIRestarting the panels did not help; unplugging and replugging each switcher's network cable did. A firmware upgrade changed nothing. Replies name the client limit, network MIDI from ATEM Software Control and broadcast stormsCame back after recoveryr/blackmagicdesignr/VIDEOENGINEERING
2022-12-04ATEM Mini ProNot statedFront panel, recording or video freezeFroze two and a half hours in; nothing respondedWedding livestreamNot statedNot statedr/blackmagicdesign
2022-12-012 M/E Constellation HDbefore 9.2.1Control lockoutStops responding when clients disconnect close togetherCustom client; switcher resends every multiview window each frameGone after 9.2.1Fixed or improvedatem-connection #132
2022-11-162 M/E Constellation HDNot statedFront panel, recording or video freezeSuperSource artifacts after 2–3 hMixEffect; switcher floods multiview and timecode statusRestart; Blackmagic reproduced itCame back after recoveryForum t=170880
2022-10-172 M/E Constellation HDNot statedMedia pool or storagePool clears at shutdown"This is normal"Not statedExpected or not a switcher faultForum t=169170
2022-08-301 M/ENot statedControl lockoutPanel and devices drop7–9 clientsRemove clientsFixed or improvedForum t=89893
2022-08-29ATEM Mini Extreme ISONot statedFront panel, recording or video freezeMacro-driven transitions hang: a 3-second transition freezes, crawls and freezes again, taking about 20 minutesMacros; re-recording the macro did not helpNothing workedUnresolvedr/blackmagicdesign
2022-08-10Constellation 8K8.6.2Client-side faultCompanion crashes on connect unless every ATEM Software Control is closedNot statedNot reproducedUnresolvedcompanion-module #204
2022-08-032 M/E Constellation HDNot statedClient-side faultCompanion module freezes when faders moveFairlight state updatesModule fixFixed or improvedcompanion-module #202
2022-07-25Television Studio HD / HD Proafter 7.5.2Settings or labels lostBlackmagic: use 7.5.2 for working media and startup stateOfficial answer"We cannot promise" a fixUnresolvedForum t=110658
2022-07-20Constellation 8KNot statedFront panel, recording or video freezeAfter hours: panel + PC lost, frame buttons dead; video finePanel, PC, dashboardHard reboot on airCame back after recoveryForum t=164258
2022-06-282 M/E Constellation HDNot statedHardware, power or heatFront LCD went black with the backlight on; the switcher otherwise workedNot statedA restart did not helpUnresolvedr/blackmagicdesign
2022-05-222 M/E Constellation HDNot statedMedia pool or storagePool not kept between power-upsVolatile by designNot statedExpected or not a switcher faultForum t=160889
2022-05-132 M/E Constellation HD8.7Client-side faultCompanion at 106% CPU; reconnects every ~15 sSwitcher sends Time + 32 multiview window commands every frameModule batching; Blackmagic fixed in 9.2.1Fixed or improvedcompanion-module #182
2022-03-16Not statedATEM Software Control 8.4Settings or labels lostStartup state not saved; it started recentlymacOS 11.6.4Saving to a file and restoring itCame back after recoveryr/blackmagicdesign
2022-03-04Television Studio 4KNot statedSettings or labels lostColour settings reset at every restart despite Save Startup StateThree URSA Broadcast G2 camerasA second user: saving the startup state does not workUnresolvedr/blackmagicdesign
2022-02-21Mini Pro ISONot statedReboot or boot hangCrashes and comes back on default settings after minutes of recording3–4 cameras over 40 m fiber HDMIUnresolved; power draw suspectedUnresolvedForum t=155760
2022-02-09Mini ExtremeNot statedSettings or labels lostRandom settings reset on power lossNot statedNot statedNot statedForum t=155082
2022-01-10ATEM Mini Pro ISONot statedReboot or boot hangPressing record makes the switcher shut off and reboot; at a job it passed four test recordings, then froze and reset on the real oneRecording to a Samsung T5 2 TB (a Seagate drive did the same)Recorded in vMix instead. A reply: a Mini Pro freezes when recording to a Samsung driveUnresolvedr/blackmagicdesign
2022-01-08Television Studio HDNot statedClient-side faultCompanion loses control after ~1.5 h; after a power blip, the Pi and ATEM Software Control can't both connectCompanion build 3645Disable/enable; reboot the switchCame back after recoverycompanion-module #168
2022-01-05ATEM Mini Pro (replacement unit)Not statedHardware, power or heatSwitching HDMI out to multiview showed green waves; after a replug only the Mic 1 ON button lit, and computers did not recognise it in recovery modeUnder 20 hours of use, left on for hours showing graphicsAnother power supply did not help. A reply in 2023 had the sameUnresolvedr/blackmagicdesign
2021-12-30Mini Extreme ISONot statedFirmware update failureMIC1 flashing 5+ min; Setup can't see itTried a "factory reset"Not statedNot statedForum t=153018
2021-12-13Television Studio HD8.6.4Settings or labels lostStill brokenUser has 6 unitsNot statedNot statedForum t=110658
2021-12-12Constellation 8K8.6.3Reboot or boot hangLess than six months old: boots halfway and locks up. The 8.6.4 update reported success, but it would not bootThe morning of a Christmas serviceBack on 8.6.3 it was unstable with vertical lines on the multiview; a second factory restore with 8.6.3 left it stable enough to broadcastCame back after recoveryr/blackmagicdesignr/VIDEOENGINEERING
2021-12-07Mini Extreme ISOATEM Software Control 8.6.4Media pool or storagePool images never loadATEM Software Control opened after switcher bootReopen ATEM Software ControlFixed or improvedForum t=152034
2021-12-05ATEM Mini Pro8.6.1 (ATEM Software Control 8.6 / 8.6.1)Client-side faultATEM Software Control crashes the moment it connects; ATEM Setup still worksWindows 10Deleting Documents/ATEM Autosave fixed it but reset the streaming settings. Replies: turning off a VPN; Windows 8 compatibility mode on Windows 11; the same on macOS Sonoma with 9.6.2Fixed or improvedr/blackmagicdesign
2021-11-15Television Studio Pro 4KNot statedReboot or boot hangShuts off at random mid-service, weeklyLight load, not hotPSU suspected; try the 12 V XLR inputNot statedForum t=150871
2021-10-261 M/E (generation not stated)Not statedEthernet deadNo link lights to any switch or control surface, but works cabled straight to a computerCables swappedNot statedNot statedr/blackmagicdesign
2021-08-01Mini ExtremeNot statedReboot or boot hangPowers on frozen, no outputSwitched off at the wall between streamsFull unplug works bestCame back after recoveryForum p=778802
2021-08-01ATEM Mini Extreme ISONot statedFront panel, recording or video freezeThree times the record button froze red and would not turn off until the unit was unplugged; the drive then held no filesRecording to a LaCie Rugged 500 GBA reply reports the same twice with a LaCie 2 TB SSDUnresolvedr/blackmagicdesign
2021-07-15Television Studio Pro 4KNot statedSettings or labels lostmultiview labels turn to "black"Power cycleFix lasts until next power cycleCame back after recoveryForum t=144570
2021-07-11Television Studio HDlatest thenSettings or labels lostmultiview labels reset except input 8RebootNot statedNot statedForum t=144353
2021-06-29ATEM MiniATEM Software Control 8.6.1Client-side faultHas problems at times; every power cycle of the switcher crashes the connected MacmacOS Big Sur; through a USB hub and also directUnplugging power for 10 s and restoring settings usually helpsCame back after recoveryr/blackmagicdesign
2021-06-20Not stated (in an ATEM Mini thread)Not statedOutput or audio failureOutput froze over and over in one day, after a year without problems or changesNot statedUnplugged the switcher each timeCame back after recoveryr/blackmagicdesign
2021-06-06Mini ExtremeNot statedSettings or labels lostSettings lost at switch-off; XML misses keysNot statedNot statedNot statedForum t=141775
2021-05-20Not statedNot statedControl lockoutOnly 4 of 10 tallies connect10 DIY Wi-Fi talliesTally-server modeFixed or improvedESP tally #44
2021-05-12Television Studio HD (2 units)8.6.1Settings or labels lostMedia, mixer, labels lost; PGM/PVW, IP, mode, macros keptNot statedClear + recovery reflash no help; 7.x fixedFixed or improvedForum t=110658
2021-05-09ATEM Mini Procurrent thenOutput or audio failureUSB feed stays blank in every app until the switcher restartsJoining Zoom breakout roomsAnother user's replacement unit did the same with a new cable and computer (2021-10); still reported in 2021-12Unresolvedr/blackmagicdesign
2021-04-29Mini ProNot statedMedia pool or storageStopped keeping its stillAfter a software updateNot statedNot statedForum t=104684
2021-04-13Television Studio HD8.5.3Settings or labels lostStartup state back to defaultStarted weeks ago, nothing changedNot statedNot statedForum t=110658
2021-03-23ATEM MiniNot statedOutput or audio failureOutput into OBS freezes about 2 minutes inNot statedFixed by an update of the computerFixed or improvedr/blackmagicdesign
2021-01-312 M/E (Production Studio 4K class)8.5.3Control lockoutAll clients lost after 2 h; video ran; ATEM Software Control asks for a firmware update4–6 clients incl. Companion, Camera Control Panel, tallyPower cycle failed; re-flashing 8.5.3 fixed itFixed or improvedForum t=133171
2021-01-31Mini Pro8.5.3Media pool or storageStills seemed lost, came back laterExtra power cycle after update?Not statedNot statedForum t=104684
2021-01-14Mini Pro8.5.2Media pool or storageXML restore empties the pool but says "completed"Not statedNot statedNot statedForum t=131735
2020-12-17Television Studio HD8.1.1 to 7.5.2Firmware update failureEthernet downgrade failed at ~70%; frozeOver EthernetPower pull, then finish over USBFixed or improvedForum t=110658
2020-12-12Mini Pro ISO8.5.3Media pool or storagePool empty after power cycleEarlier update hadn't really appliedForced USB updateFixed or improvedForum t=104684
2020-11-29Television Studio HDNot statedOutput or audio failureTwice in rehearsal the XLR inputs turned to white noise and the headphone output stopped; the analog audio section stopped while camera audio continuedThe poster ties it to clipped input signalsA power cycle restored itCame back after recoveryr/VIDEOENGINEERING
2020-11-09ATEM Mini ProNot statedSettings or labels lostAfter every power cycle the mic pans: about 32 samples of delay between left and right. Touching the delay control clears it until the next rebootA 2-frame audio delay on mic 1 saved in the startup stateBlackmagic support was looking into itCame back after recoveryr/blackmagicdesignr/blackmagicdesign
2020-11-01ATEM Mini Pro ISO8.5.1 or 8.5.2Reboot or boot hangReset itself twice in 10 minutes while streamingRecently updated firmware; warm, not hot; vents clear; power plug screwed inThe poster planned a downgradeNot statedr/blackmagicdesign
2020-10-20Constellation 8K8.1.2 (sw 8.5)Front panel, recording or video freezeCascade: panel drops, then PC, then multiview VU meters stutter, then front buttons die; video runsCompanion, Stream Decks, 4 media players, macros; isolated LAN; warm, not hotUnplug; Blackmagic says "update everything"Came back after recoveryForum t=123840
2020-10-01Older 2 M/E (the title says 1 M/E)Not statedFirmware update failureA USB firmware update crashed the laptop at the same point every time, on two laptops and cables; afterwards no multiview and the unit runs coolFirmware update over USB from a MacBook ProNot statedUnresolvedr/blackmagicdesign
2020-09-29Mini ProNot statedControl lockoutEarlier clients can't reconnect; ATEM still visibleSeveral ATEM Software Control over LAN + Wi-FiFewer clientsFixed or improvedForum t=122610
2020-09-10Not stated (in an ATEM Mini Pro ISO thread)Not statedFront panel, recording or video freezeAfter 64 minutes recording and streaming stopped; the record and stream buttons did not respond while cuts still workedISO recording to a Samsung T5 2 TB plus a YouTube streamNot statedNot statedr/blackmagicdesign
2020-08-30ATEM Mini Pro ISONot statedFront panel, recording or video freezeAt minute 32 of a livestream everything crashed and the unit did not respond; after a reboot it crashed againISO recording to an external SSD rated 533 MB/sStable after ISO recording was dropped, but all settings and stills had reset and were rebuilt liveFixed or improvedr/blackmagicdesign
2020-08-18ATEM Mini ProNot statedOutput or audio failureUSB video goes black while audio keeps workingA Teams or WebEx call startingFixed by a power cycleCame back after recoveryr/blackmagicdesign
2020-07-24Television Studio HD (+ Television Studio Pro 4K 2023)7.5.2; 9.2.2 / 8.6.5 / 7.5.2Firmware update failureWon't boot; "invalid state"; solid red SETInterrupted updateMixed; some USB reinstalls workedNot statedForum t=118314
2020-07-21Mini Pro (+ Mini Extreme 2021)8.3 / 8.6Firmware update failureFails at 70%; random recovery-mode boots; "EEPROM?"Not statedSupport; another PC saw "Blackmagic USB restore"Not statedForum t=118116
2020-07-19Mini Pro (+ Pro ISO)Not statedFront panel, recording or video freezeStream stops; ON AIR dead; 30 min–1.5 h inChurch streams; heat and HDMI source suspectedPower cycleCame back after recoveryForum p=669565
2020-07-11ATEM MiniNot statedOutput or audio failureUSB webcam picture goes black, three or four times in one eventJoining Zoom breakout rooms (2018 MacBook Pro)Rebooted the switcher and restored a backup fileCame back after recoveryr/blackmagicdesign
2020-07-07ATEM Mini ProNot statedOutput or audio failureUSB webcam picture goes black at random, two or three times within a few minutesZoom on a MacBook ProPower-cycling the switcher was the only fixCame back after recoveryr/blackmagicdesign
2020-06-202 M/E (generation not stated)Not statedFront panel, recording or video freezeFroze once; another time the audio section stopped outputting audioRunning 24/7 for over three years on a UPSA restart both timesCame back after recoveryr/VIDEOENGINEERING
2020-06-17"larger ATEMs"8.2.1 and laterSettings or labels lostBlackmagic (relayed): bug in label and media file savingNot statedRoll back to 8.1.0Not statedForum t=110658
2020-05-20Not stated (in an ATEM Mini thread)Not statedMedia pool or storageRestoring saved settings brings stills back only on the ATEM Software Control install that added them, with the files at the same paths; stills added from a second computer do not come backTwo computers running ATEM Software ControlSettings restored or rebuiltUnresolvedr/blackmagicdesign
2020-05-10Television Studio HDNot statedClient-side faultClient reconnect loop ("missed 3 pings")Blocked Node event loopLibrary fixFixed or improvedatem-connection #82
2020-04-21ATEM MiniNot statedMedia pool or storageSaving the startup state keeps the chroma key and audio levels, but not the imagesPower cycleA reply relayed Blackmagic support: image storage is volatile; save and restore insteadExpected or not a switcher faultr/blackmagicdesign
2020-04-18Television Studio HD8.2.1Settings or labels lostLabels revert; new media lost, old media survivesAfter the update7.5.2 worksFixed or improvedForum t=110658
2020-04-11Television Studio HDNot statedFirmware update failure"Update failed"; frozen 20 min; fans full, SET redNot statedUSB recovery with ATEM SetupFixed or improvedForum t=111134
2020-04-05Television Studio HD8.1.2Settings or labels lostSave Startup State doesn't workAfter 7.2 to 8.1.2Restore XML every bootCame back after recoveryForum t=110658
2020-02-04Television Studio HDNot statedHardware, power or heatDead after a power outage; no lightsCar hit a power poleInternal PSU dead; ran on 12 V XLR; others repaired twiceFixed or improvedForum t=107020
2020-02-01Mini8.1 / 8.1.1Firmware update failureStuck at "update required"; fails at 85% or 70%3 cables, 3 PCsRMA or exchange; one fixed after 24 h in update modeFixed or improvedForum t=106841
2020-01-31ATEM MiniNot statedMedia pool or storageStills in the media pool are gone after every power cyclePower cycleReplies: the media pool is held in RAM on these models, so it is saved and restored insteadExpected or not a switcher faultr/blackmagicdesignr/VIDEOENGINEERING
2020-01-282 M/E Production Studio 4KNot statedSettings or labels lostPhantom 2nd M/E; XML restore no effect; Clear Startup State failsImported macros from a Television Studio 4KNot statedNot statedForum t=106598
2019-11-02Television Studio HDbefore 8.xControl lockoutSession slots run out; only a restart frees themWi-Fi tallies roaming between APs + 3 clientsTally with one shared sessionFixed or improvedForum t=101841
2019-10-08Production Studio 4K8.0.1Control lockoutATEM Software Control can't connect after the atem-connection library didCustom Node appRestart ATEM; maintainer doesn't know whyCame back after recoveryatem-connection #61
2019-07-02Constellation 8K8.0.1Front panel, recording or video freeze"Freezes the Atem"After the update8.0 partly worked; unit replacedNot statedForum t=94114
2019-05-292 M/E Production Studio 4KNot statedMedia pool or storagePool erased on power lossVolatile by designScript re-uploads at bootExpected or not a switcher faultForum t=92211
2019-04-211 M/E Production Studio 4K7.5.2Control lockoutAll connections drop for a few seconds~3 clients on a church LANIsolate the networkCame back after recoveryForum t=89893
2019-02 to 2021Television Studio 8.1, Mini Pro 8.5.2, Studio 4K 8.0.1as listedMedia pool or storageATEM Software Control crashes importing mediaPC-specific; also a bug when resolution changed after the first uploadNot statedNot statedForum t=85919
2018-09-101 M/E Production Studio 4KNot statedHardware, power or heatWould not power on unless the power cable was unplugged and replugged several timesNot statedReturned to Blackmagic under RMANot statedr/VIDEOENGINEERING
2018-05-30Not stated (with a hardware panel)Not statedControl lockoutThe panel connected for about 5 minutes, then disconnected, over and overAll devices on 168.x.x.x addresses, a publicly routable rangeStable after moving everything to 192.168.x.xFixed or improvedr/VIDEOENGINEERING
2018-02-20, 2020-011 M/E Production Switcher; 1 M/E HDNot statedFirmware update failureUpdate loop; BSOD mid-update left PSU LED off; multiview deadWindows crash mid-updateFeared brickedUnresolvedForum p=588682
2018-01-092 M/E Broadcast Studio 4K7.2Control lockoutPanels + PC drop at the same time 3 Sundays running6 clients incl. Wi-Fi iPad and iPods; "new since 7.2"Power cycle; Blackmagic blames Wi-Fi; still seen in 2021 with no Wi-FiCame back after recoveryForum p=384298
2017-12-181 M/E Production Studio 4K (two units)Not statedHardware, power or heatThe second of two units started to die; the first had died two months earlierLive-event use for two yearsA reply moved from an ATEM 4K to another brand over similar SDI failuresNot statedr/VIDEOENGINEERING
2017-03-08Television Studio HD7.0Firmware update failureRepeated failures; fans full, SET flashing redFaulty USB cableNew cable; "don't update over LAN"Fixed or improvedForum t=57086
2015-11-182 M/E Production Studio 4K6.6.1Media pool or storage31-frame stinger takes 94 s to uploadEvery ATEM Software Control instance downloads every uploadKeep one ATEM Software Control connectedFixed or improvedForum t=41902
2015-11-011 M/E 4K + Broadcast Panel6.5Settings or labels lostPanel labels vanishIntermittentPanel power cycleCame back after recoveryForum t=41371
2015-06-211 M/E Production Studio 4K + old 1 M/ENot statedControl lockoutPC and panel locked out; still answers pingATEM Software Control + panel on a 10/100 switch; reconnects use up slotsPower cycle; one user went back to 6.3Came back after recoveryForum t=36664
2015-02-141 M/E6.3Settings or labels lostLabels and multiview layout reset; macros not savedAutosave on; Save Startup State used6.2 fixed it; 6.3 broke it againFixed or improvedForum t=32529
2015-02-122 M/E Production Studio 4Klatest thenControl lockoutTwo PCs can't connect next morningLeft on overnightNot statedNot statedForum p=32140
2014-10-072 M/ENot statedSettings or labels lostTotal factory reset at power-onNo cause foundNot statedNot statedForum t=28137
2014-081 M/E (3 units)Not statedSettings or labels lostAll back to factory settingsWeekend power outageNot statedNot statedForum t=28137
2014-02-171 M/E Production Studio 4K (2 units)Not statedHardware, power or heatOne dead on arrival; one dead after a week; fuse OKDealer saw failures on power cyclingRMANot statedForum t=19070
mid-20141 M/ENot statedSettings or labels lostFull reset incl. IP and video mode (1080i50 to 1080i59.94)Found on site; flat battery suspectedReset over USB; never againFixed or improvedForum t=28137
2013-12-19Television Studio (original)2013 softwareSettings or labels lostNo startup state; config lostPower failureModel had no save thenNot statedForum t=16673
2013-06-22Television Studiosoftware ~4.0Media pool or storageAdding media throws ATEM Software Control back to the IP dialogOne laptop onlyBuild 4.1Fixed or improvedForum t=9315
2013-03-131 M/E and Television StudioNot statedControl lockoutLocked out mid-show, no cutsATEM Software Control + Broadcast Panel; Wi-Fi router on LANNot statedNot statedForum p=32140
2013-03-13ATEM (model unclear)Not statedEthernet deadEthernet dead, no port LEDsMac mini via Cisco switch; iPhone app on Wi-FiMany power cycles; comes back, fails againCame back after recoveryForum p=32140
2013-02-191 M/E (2 units)software 3.5Control lockoutStops switching after 20 h to days; still sends packets; ATEM Software Control can't connectCustom client connects and disconnects every 4 sRestart; keep one sessionCame back after recoveryForum t=4436
2013-02-18Television Studiosoftware 3.3 / 3.4Control lockoutNo reconnect after a few connection lossesWin7 wired; wired + Wi-Fi MacsRestartCame back after recoveryForum p=32140
2013-02-15Television Studiosoftware 3.3–3.4Control lockoutNo client connects. Answers ping and UDP hello, never sends state30–40 client restarts; Wi-Fi retriesPower cycle onlyCame back after recoveryForum p=32140
undatedvariousNot statedMedia pool or storageSwitcher needs a restart; no button pushes workImage not at the exact video-mode sizeRestartCame back after recoveryMixEffect docs
undatedvarious (WebATEM)Not statedMedia pool or storagePreviews spin until switcher resetMedia pool lock held by a stuck appResetCame back after recoveryWebATEM PR #51
olderTelevision Studio (original)Not statedHardware, power or heatWall adapter overheats; unit stops after 15–20 min30 W adapterBigger adapter (search summary only)Fixed or improvedForum t=2088
undatedNot statedNot statedClient-side faultTransition freezes halfway if preview changes during Auto"ATEM feature"Won't fixExpected or not a switcher faultcompanion #392
undatedNot statedNot statedClient-side faultCompanion module fails at startupToo much sent to the module at onceCompanion-sideNot statedcompanion #3667

Dates are the incident's, or the report's when the incident date is not given. Cells are short summaries: read the source before drawing conclusions. The whole list is also available as JSON.

Report an incident

Had an ATEM freeze, drop its network or forget its settings? Tell us what happened. Every report is read before it is published, and your contact details never are.

Thank you. Your report is in the queue and will appear here once it has been checked.

Reports are published without your contact details once checked.

About this list

Multicam started this list in November 2026 while looking into control freezes on a 4 M/E Constellation HD. The rows come from public Blackmagic Forum threads (125), Reddit threads (90), GitHub issues of open-source ATEM control libraries (19) and first-hand reports (6), from 2013 to 2026. Each row links its source; replies in a thread get their own row only when they name their own model, firmware or symptom.

A row is a report, not a diagnosis. Most causes are guesses by the people involved, and the same thread can appear in several rows. This site is not affiliated with or endorsed by Blackmagic Design. ATEM is a trademark of Blackmagic Design. Updated 10 November 2026.