| 2026-11-10 | Constellation 8K | Not stated | Front panel, recording or video freeze | Became sluggish, front panel included | One control client too many was opened | Came back when that software was closed. Another user replied that this is a known issue on most Blackmagic switchersFixed or improved | First-hand report |
| 2026-11-10 | ATEM Advanced Panel | Not stated | Front panel, recording or video freeze | Panel froze | A custom input label with a Nordic letter (æ, ø or å) was sent through Companion | Power cycle, then the same label set from ATEM Software ControlFixed or improved | First-hand report |
| 2026-11-10 | 4 M/E Constellation HD | Not stated | Control lockout | Control engine freezes, many times over several years. Video passes through and ATEM Setup still works, but the front panel does not respond and ATEM Software Control cannot connect | Not known; the owner suspects a faulty unit | Power cycle. Afterwards it is sometimes fine, sometimes routing is reset and sometimes labels are back to factory defaults. Media player uploads also fail at timesCame back after recovery | First-hand report |
| 2026-11-10 | Television Studio HD | Not stated | Front panel, recording or video freeze | Front panel locks up | Front-panel buttons pressed in quick succession | Not statedNot stated | First-hand report |
| 2026-11-10 | Newer models with black front panels (ATEM switchers, Videohubs, SMPTE 2110 converters) | Not stated | Control lockout | Network control locks up until a reboot. The reporter says the symptoms could match the Constellation HD lockouts | Bursts of mDNS on the network; the reporter believes bursts under 100 packets/s crashed 2110 3x3 converters. Older models with grey front panels were not affected | RebootCame back after recovery | First-hand report |
| 2026-11-09 | 4 M/E Constellation HD | 9.6.2 or later (protocol 2.32) | Control lockout | Control froze four times in two days (2026-11-09 and 10). Ping and the web page still answered; no reply to the UDP 9910 hello for any session | Two control clients. One freeze came while a client was acknowledging 1–4 s late and the switcher was resending heavily; one came 45 s after a power cycle with prompt acknowledgements; one with that client off the network. One host on the network sent mDNS peaks of 86–96 packets/s in the minute before two of the freezes | Power cycle. After one, the mixer state was back on defaults with labels kept; after the 11-10 freeze the unit was on factory settings, labels included, and media pool uploads failedCame back after recovery | First-hand report |
| 2026-10-27 | 4 M/E Constellation 4K | Not stated | Reboot or boot hang | Fans run at full speed on power-up and the boot is unreliable; it needs several power cycles, then works normally | Not stated | Replies: power supply voltage suspected; another 4 M/E owner says theirs always starts at full fan speed, then settles; a reflash suggestedCame back after recovery | r/VIDEOENGINEERING |
| 2026-10-25 | Television Studio HD | 8.11 to 7.5.2 | Firmware update failure | "Firmware update failed" after 10 min; fans at max | Downgrade | Open; needs USBUnresolved | Forum t=144353 |
| 2026-10-22 | Television Studio HD | 8.11 / ATEM Software Control 11.0 | Settings or labels lost | Labels and media graphics not kept | "General", not one unit | Blackmagic: 7.5.2 last version with full supportUnresolved | Forum t=144353 |
| 2026-10 | Constellation HD | Not stated | Client-side fault | Meters suspected frozen after re-handshake | Level subscription is per session | Not reproduced; re-arm each sessionUnresolved | webatem #38PR #43 |
| 2026-09-29 | n/s (over VPN) | Not stated | Client-side fault | Backlog ~180 packets (3.6 s); every packet resent 7–8 times | Library dropped out-of-order packets; ATEM resends its whole unacked window each frame | Buffer and ack at onceFixed or improved | atem-connection PR #203 |
| 2026-09-09 | Mini Pro | Not stated | Firmware update failure | USB stopped working; factory reset fails at 100% | 2 PCs, several cables | No replyUnresolved | Forum t=239926 |
| 2026-09-07 | ATEM Mini Extreme ISO G2 with Micro Studio Camera 4K G2 | Not stated | Control lockout | Video is fine, but tally stays dark and HDMI camera control (iris, focus, zoom) does nothing | Raspberry Pi Zero HDMI sources on other inputs; it breaks the moment a Pi starts sending video. The poster's explanation: HDMI tally and camera control use CEC through one controller shared by all inputs | An inline HDMI CEC blocker (pin 13 cut) on each Pi. Blackmagic's lab found no fault in a minimal setup. A reply saw the same with HDMI-over-Ethernet extendersFixed or improved | r/blackmagicdesign |
| 2026-08-17, 10-14 | 2 M/E Constellation HD; Constellation 8K | 8K: 10.2 | Client-side fault | Companion drops after a day or two, never recovers | Worker process flagged frozen | OpenUnresolved | companion-module #479 |
| 2026-07-28 | Constellation 4K | 10.3 | Ethernet dead | "Seems to have solved all the problems" | One user, still testing | Not statedNot stated | Forum p=1095732 |
| 2026-06-20 | Not stated | ATEM Software Control up to 10.3 Beta 2 | Client-side fault | ATEM Software Control kept crashing | MacBook Pro M1 on macOS Tahoe 26.5.1 | Stable only on 9.6.3Fixed or improved | r/blackmagicdesign |
| 2026-06-02 | Constellation 4K | 10.x, then 9.5.1 (or 9.4) | Ethernet dead | Crash mid-event with 1 M viewers | Not stated | Downgrade restored stability; multiview glitches goneFixed or improved | Forum p=1095732 |
| 2026-05-28 | ATEM SDI Extreme ISO | Not stated | Firmware update failure | An update reached 100%, then reported failure; since then the top-left key flashes red, and reflashing every version from 8.4 to 10.2 fails | An update prompted while installing Fairlight software on a Mac | Blackmagic returned it unrepaired: no replacement parts availableUnresolved | r/VIDEOENGINEERING |
| 2026-05-18 | Constellation 4K | 10.2.1 | Ethernet dead | Still happens | Not stated | Replugging the network sometimes helpsCame back after recovery | Forum p=1095732 |
| 2026-05 | ATEM Micro Panel with 1 M/E Constellation HD | 10.2.1 / 10.2 / 10.1 / 9.6.2 | Front panel, recording or video freeze | Panel goes blank | Tried on several firmware versions | A downgrade to 9.8.3 helped brieflyCame back after recovery | r/blackmagicdesign |
| 2026-04-28 | 4 M/E Constellation HD | 10.2.1 | Client-side fault | Companion feedback lags 1–2 s after hours | Lossy-network handling in the module | Module 4.3.1Fixed or improved | companion-module #447 |
| 2026-03-25 | 1 M/E Constellation (several units) | Not stated | Media pool or storage | Power outages and reboots wipe the media pool, so a show file has to be loaded every time | Daily use | The poster's automation of the reload is inconsistentUnresolved | r/blackmagicdesign |
| 2026-02-26 | 4 M/E Constellation 4K | Not stated | Ethernet dead | Unreachable after a few minutes on; self-assigns 169.254.1.9 | Static or DHCP, direct cable | Works briefly after a long unplugCame back after recovery | Forum p=1095732 |
| 2026-02-18 | 2 M/E Constellation HD | 10.1 | Client-side fault | Client at 30–40% CPU when idle | Switcher still sends 32 multiview commands per frame | Library 3.9.0Fixed or improved | atem-connection #190 |
| 2026-02-08 | ATEM Micro Panels with two 2 M/E Constellation 4K and four Constellation HD | 10.2.1 | Front panel, recording or video freeze | Panels go blank on all six remote-production systems | Firmware 10.2.1 | Not statedUnresolved | r/blackmagicdesign |
| 2026-01-27 | 1 M/E Advanced Panel 10 with Constellation 8K | 10.2 | Reboot or boot hang | The panel boot-loops every 12 s and never gets past "connecting", but only when pointed at the 8K; the 8K answers Companion, ATEM Software Control and ping, and the panel works with another ATEM | Worked for 3 years; updated to 10.2 five weeks earlier | A direct cable, static and DHCP addressing, 10.2.1 and a rollback to 9.5 did not helpUnresolved | r/VIDEOENGINEERING |
| 2026-01-27 | Constellation 8K (another owner) | Not stated | Hardware, power or heat | Same panel boot loop, traced to the 8K's Ethernet controller | Started right after a UPS was added to the metal rack | The dealer replaced the unit; the repair estimate for the board was $1600Fixed or improved | r/VIDEOENGINEERING |
| 2026-01-13 | ATEM Micro Panel with 4 M/E Constellation 4K | 10.2 | Front panel, recording or video freeze | The panel goes blank and unresponsive after a while; replugging USB-C sometimes revives it for a time. ATEM Setup reads the panel inconsistently | Panel and switcher updated to 10.2 | Other users: off every 5–40 minutes, or every 10 minutes or so during shows. Downgrades often fail with "Update Failed, Check Connection". Blackmagic could not make it fail. Keeping the panel on old firmware and drivers from a separate laptop worksUnresolved | r/blackmagicdesign |
| 2025-12-05 | 2 M/E Constellation 4K | Not stated | Ethernet dead | Network lost after a good day | Not stated | Not statedNot stated | Forum p=1095732 |
| 2025-12-01 | Mini Pro (2 units) | latest | Settings or labels lost | Stream bandwidth fields blank after power cycle | Remote sites | Not statedNot stated | Forum t=110658 |
| 2025-11-26 | HD8 ISO | Not stated | Firmware update failure | ATEM Setup errors over Ethernet and USB | Wants a factory reset, which needs Setup | Not statedNot stated | Forum t=230636 |
| 2025-11-02 | 2 M/E Constellation HD | Not stated | Control lockout | Mid-event it stopped responding over Ethernet and USB: still pingable and visible in ATEM Setup, but ATEM Software Control could not connect from several computers | Companion and Hollyland tally, 3 devices; two switches, no internet; another Constellation HD and a HyperDeck on the network; the software had dropped and reconnected earlier that day | Everything came back at once after a power cycle. Replies: seen twice in a couple of years; seen on busy networks; a colleague's claim of a memory leakCame back after recovery | r/blackmagicdesign |
| 2025-10-13 | 1 M/E Constellation (HD or 4K not stated) | latest then | Front panel, recording or video freeze | When one particular Mac connects, the switcher and its program output freeze, and it cannot be controlled even from the front panel until power-cycled | That Mac: ATEM Software Control 10.0 on macOS Sequoia over a Wi-Fi router, at most the third connection; it controls other ATEM models fine | A reply had the same with their ConstellationCame back after recovery | r/blackmagicdesign |
| 2025-09-21 | 2 M/E Constellation HD | 10.0 | Front panel, recording or video freeze | Lockout a few minutes after every boot | Restored a settings file saved on "9.7.2" | Rebuilt settings by hand, no old file: fixedFixed or improved | Forum t=175982 |
| 2025-08-30 | Mini Pro | ATEM Software Control 9.7.1 | Settings or labels lost | AUTO transition reverts to CUT | Not stated | Firmware 9.5.1 or laterFixed or improved | Forum t=226593 |
| 2025-08-24 | ATEM Mini Pro ISO | Not stated | Settings or labels lost | Changes settings on its own, even mid-record: audio sources, and camera settings until the lens focus stops working. The startup state sometimes sticks | After a firmware update, following about 2 years without problems; support suspected MIDI control | A replacement unit had no problems; running without ATEM Software Control was slightly more stableFixed or improved | r/blackmagicdesign |
| 2025-08-24 | Television Studio HD8 ISO | Not stated | Settings or labels lost | Often goes haywire when ATEM Software Control connects | Seemed to start with a firmware update | Not statedNot stated | r/blackmagicdesign |
| 2025-08-04 | 1 M/E Production Studio 4K | latest | Control lockout | Drops tied to the number of clients | 3 Stream Decks + ATEM Software Control | Not statedNot stated | Forum t=89893 |
| 2025-07-29 | Constellation 8K | 9.6.3 (and earlier versions) | Control lockout | About 10 lockups in 2 years: network control lost (2 M/E Advanced Panel and ATEM Software Control), still answers ping and ATEM Setup over USB, front-panel buttons dead except the Settings menu, audio bars on the front screen stuck | Across different firmware versions, I/O and resolutions | A power cycle every time. A regular in the thread called it a common issue that has improved with later updates, and advised less network noise and the switcher's own L3 subnet or VLAN. Another owner had the same in 2025-10Came back after recovery | r/blackmagicdesign |
| 2025-07-29 | Constellation 8K (another owner) | Not stated | Control lockout | Same problem | Not stated | The dealer swapped the unit for a new oneFixed or improved | r/blackmagicdesign |
| 2025-05-18 | Television Studio HD (1 of 2) | 8.1.1 | Settings or labels lost | Stopped saving startup state; twin unit fine | Worked weeks before | No replyUnresolved | Forum t=221752 |
| 2025-03-03 | Constellation 4K | Not stated | Ethernet dead | "Same issue" | Not stated | Asks about RMAUnresolved | Forum p=1095732 |
| 2025-02-07 | 4 M/E Constellation (HD or 4K not stated) | 9.5.1 | Reboot or boot hang | Froze completely an hour after a service; after power cycles it would not fully boot: camera 1 on every output, no display, only LOCK and MIX lit, no software control | Not stated | A factory reset gave about 15 minutes; after a second factory reset and a forced update to 9.6.2 the XML loaded and it ran normally for 9 hoursFixed or improved | r/VIDEOENGINEERING |
| 2025-01-12 | Not stated | ATEM Software Control 9.0.2 | Settings or labels lost | No longer saves the startup state, whatever they try | macOS Monterey 12.2 | Nothing workedUnresolved | r/blackmagicdesign |
| 2024-12-27 to 2025-05-08 | 2 M/E (Constellation?) + Micro Panel | ATEM Software Control 9.7 | Client-side fault | ATEM Software Control + Micro Panel lock up after hours; switcher panel and Companion fine | Panel direct to PC | Restart the appCame back after recovery | Forum p=1110384 |
| 2024-12-14 | HD8 | 9.0.2 | Hardware, power or heat | White particles on PGM and multiview; network control and tally lost | Leakage current through an SDI audio de-embedder | Removing it restored tallyFixed or improved | Forum p=1047304 |
| 2024-12-08 | ATEM Mini Extreme | Not stated | Reboot or boot hang | Restarts on its own; sometimes boots only partway with only Mic 1 lit and needs several tries | Church use; happens without overheating (fan under it) | Power cycle or restartUnresolved | r/blackmagicdesign |
| 2024-11-28 | Constellation 8K | Not stated | Front panel, recording or video freeze | All inputs and outputs show moiré | After many hours, 2160p50 | Unplug; Blackmagic contactedCame back after recovery | Forum p=1102449 |
| 2024-11-06 | 2 M/E Constellation 4K (new) | Not stated | Ethernet dead | No network, no ping | NTP off didn't help | USB only; restart didn't helpUnresolved | Forum p=1095732 |
| 2024-11-06 | SDI Extreme ISO | Not stated | Media pool or storage | Uploads never finish; Ethernet LED lit with no cable | Any format | No answerUnresolved | Forum t=211281 |
| 2024-10-31 | ATEM Mini Pro ISO (second-hand report) | 9.5.1, ATEM Software Control 9.6.2 | Client-side fault | ATEM Software Control crashes every few seconds on the Switcher, Media, Audio and Camera buttons | Not stated | Not statedNot stated | r/blackmagicdesign |
| 2024-10-28 | 2 M/E Constellation | Not stated | Client-side fault | Needs several connect tries | PyATEMMax; session id not reset | OpenUnresolved | PyATEMMax #50#43 |
| 2024-10-12 | 4 M/E Constellation 4K | 9.6.2 | Ethernet dead | Port "fully blind": no ping, no panel, no traffic | Random moments | Once USB + NTP off; next day a restartCame back after recovery | Forum p=1095732 |
| 2024-10-07 | Advanced Panel 10 on 2 M/E Production Studio 4K | 9.6.2 | Reboot or boot hang | Panel freezes, then reboots (switcher fine) | Navigating right in the Settings menu | Back to 9.6.1 fixed it (2 users)Fixed or improved | Forum p=1089521 |
| 2024-09-30 | 2 M/E Constellation HD | Not stated | Output or audio failure | Outputs stop working; a reboot brings them back, sometimes for a while, sometimes only briefly. The multiview stays fairly solid | In a hot teaching-desk rack | The owner concluded the unit was broken and planned to buy a new oneUnresolved | r/VIDEOENGINEERING |
| 2024-09-27 | 4 M/E Constellation HD | 9.6.2 | Control lockout | ATEM Software Control shows "No Switcher Connected" every minute or so, back in seconds | MixEffect stayed connected; no link drop | Lasts until power-offCame back after recovery | Forum t=208261 |
| 2024-09-27 | 4 M/E Constellation HD | 9.6.2 | Firmware update failure | Update needs "allow administration from USB and Network" | That setting is USB-only | Not statedNot stated | Forum t=208261 |
| 2024-09-13 | 4 M/E Constellation 4K | Not stated | Client-side fault | No client connects through AtemProxy | Proxy untested past 8.6.4 | OpenUnresolved | AtemProxy #5 |
| 2024-09-06 | Mini Extreme + ISO | Not stated | Front panel, recording or video freeze | Stream and record buttons freeze; cache fills | Hours of high-quality streaming + SSD; 27 °C room | UnresolvedUnresolved | Forum p=990314 |
| 2024-09-05 | 2 M/E Constellation | Not stated | Control lockout | Hours after boot: short drops, then Companion + ATEM Software Control lost | Companion on a Pi, Wi-Fi ATEM Software Control, shared rack router | Pull power; a different router fixed itFixed or improved | Forum p=1078877 |
| 2024-09-05 | Not stated (in a Constellation 8K thread) | Not stated | Reboot or boot hang | Vertical lines on the multiview, will not boot most of the time, cannot update | Not stated | Not statedUnresolved | r/blackmagicdesign |
| 2024-08-28 | Not stated | ATEM Software Control 9.6 to 9.6.2 (macOS) | Client-side fault | ATEM Software Control crashes when the Media Player tab opens, and when the XML configuration is reloaded | macOS | Downgrading the software to 9.5.1 fixed it; a second user had the same, still on 9.6.2Fixed or improved | r/blackmagicdesign |
| 2024-08-27 | Production Studio 4K | Not stated | Control lockout | Pings, but ATEM Software Control says "Not connection" | First setup, direct cable | No reply; weak evidenceUnresolved | Forum p=1075791 |
| 2024-08-27 | switcher in a 4 M/E HD thread | to 9.5 | Firmware update failure | Firmware failure halfway | Not stated | RMA; Blackmagic said the Ethernet port was "shot"Not stated | Forum p=1096204 |
| 2024-08-26 | 4 M/E Constellation HD | 9.6 package (HD firmware 9.2.1) | Ethernet dead | No network after update; USB-C only | DHCP, static, direct cable | LOCK-button recovery reflash with Blackmagic failed; downgrades failedUnresolved | Forum p=1096204 |
| 2024-08-21 | Not stated (in an ATEM Mini Extreme ISO thread) | Not stated | Front panel, recording or video freeze | Physical buttons hang about 5 minutes after the first cold power-up of the day, while software control works | First cold start of the day, two days running | A power cycle fixes it until the next cold startCame back after recovery | r/blackmagicdesign |
| 2024-08-14 | ATEM Mini Pro | Not stated | Output or audio failure | USB webcam feed freezes after 5–6 minutes and the computer stops recognising the device; front-panel and software control still work | Streamlabs; the same on a laptop and in the Camera app | Blackmagic support said most likely a soldering issue; returnedNot stated | r/VIDEOENGINEERING |
| 2024-07-19 | Mini Pro | Not stated | Hardware, power or heat | Runs very hot; cache fills in 2 min | Not stated | User calls it "cooked"Not stated | Forum p=1065058 |
| 2024-07-14 | Not stated (in an ATEM Mini Extreme ISO thread) | 9.5 / 9.5.1, then 9.0.2 | Ethernet dead | Network dead after the update; no DHCP lease at all | Firmware update to 9.5 / 9.5.1 | Rolling back to 9.0.2 did not helpUnresolved | r/blackmagicdesign |
| 2024-07-09 | SDI Extreme ISO | Not stated | Front panel, recording or video freeze | "Frozen in time"; buttons show last state; recording stopped | 6 cameras, panel, CCU, 8-source ISO | Power cycle; Wi-Fi reconnect flood suspectedCame back after recovery | Forum p=1062140 |
| 2024-07-09 | ATEM Mini Extreme ISO | 9.5 / 9.5.1 | Ethernet dead | After the update it vanished from the network. The link LEDs are inverted: on with no cable, off with a cable | Firmware update to 9.5; static and DHCP, direct and through switches, several cables | A recovery-mode reflash did not help; USB control still works. Two more owners reported the same in 2024-11 and 2025-02, USB onlyUnresolved | r/blackmagicdesign |
| 2024-07-09 | ATEM SDI Extreme ISO (two of four units) | 9.5.x | Client-side fault | Two of four updated units crash ATEM Software Control when it connects, over USB or Ethernet, on a fresh computer and after a recovery reflash | Firmware update to 9.5.x | Suggestions: turn off IPv6 on the network adapter; the software may crash when the switcher firmware is newer than itNot stated | r/VIDEOENGINEERING |
| 2024-06-28 | Not stated (in an ATEM Mini Pro thread) | Not stated | Front panel, recording or video freeze | About 4 hours in, the recording counter stops with no other sign, and recording cannot be stopped | Samsung T7 and SanDisk Extreme Pro drives | Power cycle or restartCame back after recovery | r/blackmagicdesign |
| 2024-06-24 | Constellation 8K | 9.5 to 9.6.2 | Front panel, recording or video freeze | Hardware buttons freeze | Pressing intercom buttons; 2 units | Not fixed in 9.5.1 or 9.6.2Unresolved | Forum p=1085517 |
| 2024-06-23 | Mini Pro | Not stated | Front panel, recording or video freeze | "Crashed" 3 times at a wedding | Recording to SSD; Streaming Bridge | Restart all; mixed-up PSU or cable suspectedCame back after recovery | Forum p=1065058 |
| 2024-06-21 | Mini Pro ISO | 9.5 | Reboot or boot hang | Reboots, often in a loop, with an SSD in | ISO recording to an approved SSD | Correct PSU fixed itFixed or improved | Forum p=1057144 |
| 2024-06-02 | Constellation 4K | Not stated | Control lockout | Froze when too many control devices were connected | Many control devices | Stopped after the number of devices was reducedFixed or improved | r/blackmagicdesign |
| 2024-06-02 | Not stated (in a Constellation thread) | Not stated | Control lockout | Freezes although the number of devices is stable and under the limit | Not stated | Blackmagic was investigatingUnresolved | r/blackmagicdesign |
| 2024-06-02 | Constellation 8K | Not stated | Front panel, recording or video freeze | The poster thinks pressing the PTT button for the front headset port crashes the switcher | Front-panel intercom PTT button | Not statedNot stated | r/blackmagicdesign |
| 2024-06-02 | ATEM Mini Extreme | Not stated | Front panel, recording or video freeze | Buttons unresponsive for a minute mid-show, then came back | Not stated | Recovered by itselfCame back after recovery | r/blackmagicdesign |
| 2024-06-02 | ATEM SDI Extreme ISO | Not stated | Front panel, recording or video freeze | Lost recorded footage | Recording to an approved Samsung T5 | Not statedNot stated | r/blackmagicdesign |
| 2024-06-02 | ATEM Mini Extreme (two units) | Not stated | Output or audio failure | HDMI output 2 died | Not stated | Not statedNot stated | r/blackmagicdesign |
| 2024-05-16 | Constellation 8K | 9.3.3 | Control lockout | HyperDeck, Videohub panel, Skaarhoj links fail; discovery greyed out | After the update | Factory reset works until next reboot; some went back to 8.6.2Came back after recovery | Forum t=201543 |
| 2024-05-13 | HD8 ISO | 9.0.2 | Front panel, recording or video freeze | Buttons and fader dead; picture and meters run; ATEM Software Control has no effect | Factory internal drive | Power off; file lost; replacement unit same (09-25)Unresolved | Forum p=1047304 |
| 2024-05-12 | ATEM Mini Pro and Mini Extreme | latest then | Control lockout | Crashes unless the control software is not used; unplugging the Ethernet cable unfreezes it after a minute or two | ATEM Software Control on PC and Mac | Support emailed twice with no replyCame back after recovery | r/blackmagicdesign |
| 2024-05-12 | Television Studio HD | Not stated | Control lockout | At the end of a service it lost network control from ATEM Software Control and a Stream Deck. After a reboot the software saw it but could not connect, while ping worked and local buttons worked | Not stated | A reply had the same each time from a firmware and software version mismatchUnresolved | r/blackmagicdesign |
| 2024-05-06 | ATEM SDI Extreme ISO (two units) | Not stated | Front panel, recording or video freeze | Locking up | ISO recording on half the inputs, USB webcam out, 3 SDI outputs | Replies: dropped Wi-Fi clients fill the connection slots and lead to lockups; another user power-cycled once with ISO recording onCame back after recovery | r/VIDEOENGINEERING |
| 2024-05-01 | Mini Pro ISO | Not stated | Settings or labels lost | Settings messed up | Blackmagic's reset XML for another model | Not statedNot stated | Forum t=156999 |
| 2024-04-12 | 1 M/E Production Studio 4K (2 units) | Not stated | Ethernet dead | Network settings don't persist; PC can't see it | Direct or through a switch | Downgrade didn't helpUnresolved | Forum p=1039690 |
| 2024-04-08 | Mini Pro ISO | Not stated | Front panel, recording or video freeze | Whole system freezes on record; stop freezes after an update | Streaming Bridge + ISO record | Power down; can't stream and ISO-record togetherCame back after recovery | Forum p=1034468 |
| 2024-03-22 | ATEM SDI Extreme ISO | Not stated | Front panel, recording or video freeze | Recordings failed near the end of a show: stop did not respond on the button or in software while the multiview showed them rolling. The files had frozen video and continuing audio | ISO recording | Power cycle or restartNot stated | r/VIDEOENGINEERING |
| 2024-03-22 | ATEM Mini Extreme ISO | Not stated | Output or audio failure | The projector output dipped several times, then went out completely while the multiview stayed fine. The unit was extremely hot | 5 inputs, 2 outputs through converters | Not statedNot stated | r/VIDEOENGINEERING |
| 2024-03-22 | ATEM SDI Extreme ISO (another owner) | Not stated | Front panel, recording or video freeze | Recordings fail and will not stop, about three times in three years | Samsung T7 drive implicated | A power cycle fixes it but spoils the recordings. Another owner's unit jammed on a test recordingCame back after recovery | r/VIDEOENGINEERING |
| 2024-03-14 | Television Studio HD8 ISO | Not stated | Control lockout | Several desk lockups; a power cycle is the only fix | Several Wi-Fi tally lights connected to the switcher | Only one tally connects to the switcher now; the others take their state from itFixed or improved | r/blackmagicdesign |
| 2024-03-12 | SDI Pro ISO | 9.6 | Front panel, recording or video freeze | After 2–3 h: tallies stop, panel lights freeze, recording stops | 3 Wi-Fi tallies on busy outdoor Wi-Fi | Ethernet tally server + better cooling: no more hangsFixed or improved | ESP tally #119r/blackmagicdesign |
| 2024-02-22 | ATEM Mini Extreme ISO (new) | Not stated | Hardware, power or heat | Found off and hot 20 minutes after being plugged in, and never turned on again | Vents clear, original power supply | Not statedUnresolved | r/blackmagicdesign |
| 2024-02-21 | 1 M/E Production Studio 4K | latest, then 8.10 | Control lockout | ATEM Software Control drops its connection right after connecting, while running macros still execute | Not stated | Rolling back firmware did not helpUnresolved | r/blackmagicdesign |
| 2024-02-19 | 4 M/E Broadcast Studio 4K | 9.3.2 | Control lockout | Panel + ATEM Software Control lose connection daily | Camera Control Panel attached | Unplug the Camera Control PanelFixed or improved | Forum p=1022261 |
| 2024-02-19 | 2 M/E Constellation HD | 9.3.2 package | Control lockout | ATEM Software Control + panel lose connection daily, for good | Old 1 M/E panel + GPI/Tally box | Restart every time; no replyUnresolved | Forum p=1022261 |
| 2024-02-16 | 1 M/E Production Studio 4K (three units) | Not stated | Control lockout | After 11 months a custom switching service could no longer connect to any of the three switchers, while remote ATEM Software Control still worked; a spare switcher behaved the same | Containerised control code over a VPN; nothing changed on the network | Not statedUnresolved | r/blackmagicdesign |
| 2024-02-15 | Mini | 8.6 | Client-side fault | HDMI input blanks every hour (excluded: source fault) | Same with Micro Converters, no ATEM | Not an ATEM faultExpected or not a switcher fault | Forum p=1021418 |
| 2024-02-12 to 05-07 | HD8 ISO; Mini Pro ISO | Not stated | Front panel, recording or video freeze | Record button freezes on 10+ min recordings; files lost | Internal drive; Samsung T5 | Pull power; USB 3 cables fixed one userFixed or improved | Forum p=1044900 |
| 2024-02-04 | Not stated (in a 2 M/E Constellation HD thread) | Not stated | Firmware update failure | After a reboot an update stuck at 99%; then the fan ran continuously with only the LOCK button lit | Firmware update | Not statedUnresolved | r/blackmagicdesign |
| 2024-01-14 | 4 M/E Constellation HD (2 units + a 2nd user) | Not stated | Settings or labels lost | multiview and keyer settings reset at power-up | 1 M/E Advanced Panel on each; "no rhyme or reason" | Restore XML; no Blackmagic replyCame back after recovery | Forum t=195044 |
| 2024-01-14 | ATEM Mini Pro | latest then | Output or audio failure | Freezes mid-cut, then outputs a black image over USB | Three 1080p cameras, over six months | Sometimes the OBS source also had to be removed and added againCame back after recovery | r/blackmagicdesign |
| 2023-12-26 | ATEM Mini Extreme ISO | Not stated | Front panel, recording or video freeze | Froze while ISO recording to an SSD | Control laptop also connected over USB-C | Using Ethernet only for control made it much more stableFixed or improved | r/VIDEOENGINEERING |
| 2023-12-13 | 1 M/E Constellation HD | Not stated | Media pool or storage | All media lost on restart | Volatile | Refill from a computerExpected or not a switcher fault | Forum t=193674 |
| 2023-12-13 | ATEM Mini Pro | Not stated | Front panel, recording or video freeze | Repeatedly stops recording and freezes: recording cannot be stopped or started while everything else works. Of a 2-hour podcast, 24 minutes were saved | VectoTech 4 TB drive (540 MB/s), three cameras | Power cycle or restartUnresolved | r/blackmagicdesign |
| 2023-12-06 | ATEM Mini Pro ISO | latest then | Front panel, recording or video freeze | Froze with no switching; the record stop button worked after about 10 presses. Another time it froze after about 4.5 hours of switching | On the network with control software | Replies: the same two weeks earlier; "happening more and more often"Came back after recovery | r/blackmagicdesignr/VIDEOENGINEERING |
| 2023-12-06 | ATEM Mini Extreme | Not stated | Front panel, recording or video freeze | Froze the same way | Heat suspected | Added fansFixed or improved | r/VIDEOENGINEERING |
| 2023-11-24 | ATEM Mini Extreme | Not stated | Front panel, recording or video freeze | The fan gets louder at random and the unit freezes, with no HDMI switching | A reply suggests overheating | Unplugging every cable and restarting, sometimes several timesCame back after recovery | r/blackmagicdesign |
| 2023-10-12 | Constellation 2 M/E (HD per poster) | Not stated | Front panel, recording or video freeze | ATEM Software Control dead, multiview audio meters frozen, front panel dead; video runs | Cold outdoors, so not heat; generator power | Reboot; "happened to me recently as well"Came back after recovery | Forum p=990314 |
| 2023-10-08 | SDI Extreme ISO | Not stated | Front panel, recording or video freeze | App + switcher frozen; buttons dead; program, stream, record run | All-day church stream; second time; heat suspected | Reboot always worksCame back after recovery | Forum p=990314 |
| 2023-09-18 | HD8 ISO | 9.0.1 | Front panel, recording or video freeze | Record won't stop | ISO, 4 cameras, internal drive | Pull powerCame back after recovery | Forum p=1044900 |
| 2023-09-11 | Constellation 8K | 9.x | Control lockout | Clients drop; sometimes "hanging up the Atem" | 8 clients incl. 2 Companion; same rig fine on a 4 M/E on 8.x | Separate VLANFixed or improved | Forum t=101841 |
| 2023-09-06 | ATEM Mini Pro | Not stated | Control lockout | Twice during livestreams it stopped responding for a few minutes: the USB stream continued, but no switching from the Stream Deck, ATEM Software Control or the front panel | About 5 connections: OBS over USB, ATEM Software Control, Companion with a Stream Deck and 3 DIY Wi-Fi tally lights, on a dedicated router | Recovered by itself both times, after which Companion and the tallies had lost the switcher. The poster suspects the connection limit; a reply had the same without tally lightsCame back after recovery | r/blackmagicdesign |
| 2023-09-03 | 1 M/E | Not stated | Control lockout | All devices drop at once, up to minutes | 3 PCs + panel on main LAN | Cable swap helped for weeksFixed or improved | Forum t=89893 |
| 2023-07-11 | Constellation 8K | Not stated | Hardware, power or heat | Hot side 43 °C at ~27 °C room | Not stated | "Not unusual"; leave 1U above and belowExpected or not a switcher fault | Forum t=184473 |
| 2023-06-26 | 4 M/E Constellation HD | Not stated | Front panel, recording or video freeze | Lockout | Right after making macros and saving a backup config | Pulling Ethernet didn't help; reboot didCame back after recovery | Forum t=175982 |
| 2023-05-22 | Television Studio Pro 4K | Not stated | Settings or labels lost | Aux remap lost | Never saved (user error) | Save, then wait up to a minuteFixed or improved | Forum t=181756 |
| 2023-05-19 | 4 M/E Constellation HD | Not stated | Hardware, power or heat | Surface 32–35 °C at 21–22 °C room | Blackmagic asked for temps; a cooled enclosure still locked up | Heat not shown to be the causeNot stated | Forum t=175982 |
| 2023-05-09 | Television Studio Pro 4K | Not stated | Firmware update failure | Only fan and network light; all black | After an ATEM Setup update | Not statedNot stated | Forum t=181000 |
| 2023-04-23 | Television Studio Pro HD | Not stated | Control lockout | Answers ping, but ATEM Software Control cannot connect | Duplicate IP address with a PTZ joystick controller | A reply: Windows 8 compatibility mode for ATEM Software Control and ATEM Setup on Windows 11Fixed or improved | r/blackmagicdesign |
| 2023-04-19 | 4 M/E Constellation HD | Not stated | Hardware, power or heat | Control lockouts | Not stated | Owner asked for a replacementNot stated | Forum t=175982 |
| 2023-04 to 2024-10 | HD8 ISO | Not stated | Hardware, power or heat | Noisy fans; bad display; multiview windows fail until reboot | From day one | Not statedNot stated | Forum p=1092616 |
| 2023-03-27 | 1 M/E 4K | Not stated | Ethernet dead | Lost its connection to the panel and ATEM Software Control and no longer shows on the network; video and front-panel buttons still work | Classroom studio | Not statedNot stated | r/blackmagicdesign |
| 2023-03-27 | 1 M/E 4K (another owner) | Not stated | Ethernet dead | The network port failed | Not stated | Replaced with a 2 M/E Constellation HDFixed or improved | r/blackmagicdesign |
| 2023-03-22 | 2 M/E + 4 M/E Constellation HD | Not stated | Hardware, power or heat | Outputs and multiview flash black; some outputs dead until power cycle | External reference (Blackmagic, AJA sync) | Distributor can't replicateUnresolved | Forum t=176582 |
| 2023-03-14 | ATEM Mini Extreme ISO | Not stated | Front panel, recording or video freeze | First it answered ping but not ATEM Software Control. Later, mid-stream, the physical buttons stopped responding and showed a wrong state while the multiview, stream and software control were fine | Not stated | Not reproduced in a 5-hour test. A reply had the same during a big-stream install, with a frozen streamCame back after recovery | r/blackmagicdesign |
| 2023-03-02 | 4 M/E Constellation HD | before 9.0.1 | Front panel, recording or video freeze | Same faults | Sent to Blackmagic | "Can't replicate"; a loaner 8K workedUnresolved | Forum t=176582 |
| 2023-03 | 4 M/E + 2 M/E Constellation HD | before 9.0.1 | Settings or labels lost | Wrong colour space after power cycle | External reference in use | Not statedNot stated | Forum t=176582 |
| 2023-02-27 | 1 M/E Production Studio 4K | Not stated | Media pool or storage | Media pool reset at every power-off | Power-off | Restoring the saved XML brought the media back. A reply says firmware above 7.5.x breaks some features on this modelExpected or not a switcher fault | r/blackmagicdesign |
| 2023-02-13 | 4 M/E Constellation HD | Not stated | Front panel, recording or video freeze | Source buttons and Cut/Auto dead; menu and knob work; outputs hold; panel, tally, software all drop | Start of the lockout thread | Power cycleCame back after recovery | Forum t=175982 |
| 2023-02 | 4 M/E Constellation HD | before 9.0.1 | Front panel, recording or video freeze | Latency, dropped frames, random full lockup; SuperSource boxes lag | Not stated | Blackmagic email: 9.0.1 fixes it; some owners returned unitsNot stated | Forum t=176582 |
| 2023 (thread) | 4 M/E Constellation HD | Not stated | Front panel, recording or video freeze | Refuses new clients at ~9; 5 devices don't last 24 h; Blackmagic's tally box makes it worse | Panel, tally, ATEM Software Control, PlayDeck, Companion | Fewer clients helpedFixed or improved | Forum t=175982 |
| 2023 (thread) | 2 M/E Constellation HD (3 users) | Not stated | Front panel, recording or video freeze | Lockouts | Cuebi Wi-Fi tally; Companion (weekly); tablet + ATEM Software Control (twice in 3 h) | Power cycleCame back after recovery | Forum t=175982 |
| 2022-12-23 | 1 M/E (15 switchers, generation not stated) | Not stated | Control lockout | Every couple of days the software panels lose all 15 switchers at the same time; other devices are unaffected | One broadcast domain with multicast video; each studio a consumer switch on its own subnet uplinked to an L3 core; static IPs, all wired, no tally or MIDI | Restarting the panels did not help; unplugging and replugging each switcher's network cable did. A firmware upgrade changed nothing. Replies name the client limit, network MIDI from ATEM Software Control and broadcast stormsCame back after recovery | r/blackmagicdesignr/VIDEOENGINEERING |
| 2022-12-04 | ATEM Mini Pro | Not stated | Front panel, recording or video freeze | Froze two and a half hours in; nothing responded | Wedding livestream | Not statedNot stated | r/blackmagicdesign |
| 2022-12-01 | 2 M/E Constellation HD | before 9.2.1 | Control lockout | Stops responding when clients disconnect close together | Custom client; switcher resends every multiview window each frame | Gone after 9.2.1Fixed or improved | atem-connection #132 |
| 2022-11-16 | 2 M/E Constellation HD | Not stated | Front panel, recording or video freeze | SuperSource artifacts after 2–3 h | MixEffect; switcher floods multiview and timecode status | Restart; Blackmagic reproduced itCame back after recovery | Forum t=170880 |
| 2022-10-17 | 2 M/E Constellation HD | Not stated | Media pool or storage | Pool clears at shutdown | "This is normal" | Not statedExpected or not a switcher fault | Forum t=169170 |
| 2022-08-30 | 1 M/E | Not stated | Control lockout | Panel and devices drop | 7–9 clients | Remove clientsFixed or improved | Forum t=89893 |
| 2022-08-29 | ATEM Mini Extreme ISO | Not stated | Front panel, recording or video freeze | Macro-driven transitions hang: a 3-second transition freezes, crawls and freezes again, taking about 20 minutes | Macros; re-recording the macro did not help | Nothing workedUnresolved | r/blackmagicdesign |
| 2022-08-10 | Constellation 8K | 8.6.2 | Client-side fault | Companion crashes on connect unless every ATEM Software Control is closed | Not stated | Not reproducedUnresolved | companion-module #204 |
| 2022-08-03 | 2 M/E Constellation HD | Not stated | Client-side fault | Companion module freezes when faders move | Fairlight state updates | Module fixFixed or improved | companion-module #202 |
| 2022-07-25 | Television Studio HD / HD Pro | after 7.5.2 | Settings or labels lost | Blackmagic: use 7.5.2 for working media and startup state | Official answer | "We cannot promise" a fixUnresolved | Forum t=110658 |
| 2022-07-20 | Constellation 8K | Not stated | Front panel, recording or video freeze | After hours: panel + PC lost, frame buttons dead; video fine | Panel, PC, dashboard | Hard reboot on airCame back after recovery | Forum t=164258 |
| 2022-06-28 | 2 M/E Constellation HD | Not stated | Hardware, power or heat | Front LCD went black with the backlight on; the switcher otherwise worked | Not stated | A restart did not helpUnresolved | r/blackmagicdesign |
| 2022-05-22 | 2 M/E Constellation HD | Not stated | Media pool or storage | Pool not kept between power-ups | Volatile by design | Not statedExpected or not a switcher fault | Forum t=160889 |
| 2022-05-13 | 2 M/E Constellation HD | 8.7 | Client-side fault | Companion at 106% CPU; reconnects every ~15 s | Switcher sends Time + 32 multiview window commands every frame | Module batching; Blackmagic fixed in 9.2.1Fixed or improved | companion-module #182 |
| 2022-03-16 | Not stated | ATEM Software Control 8.4 | Settings or labels lost | Startup state not saved; it started recently | macOS 11.6.4 | Saving to a file and restoring itCame back after recovery | r/blackmagicdesign |
| 2022-03-04 | Television Studio 4K | Not stated | Settings or labels lost | Colour settings reset at every restart despite Save Startup State | Three URSA Broadcast G2 cameras | A second user: saving the startup state does not workUnresolved | r/blackmagicdesign |
| 2022-02-21 | Mini Pro ISO | Not stated | Reboot or boot hang | Crashes and comes back on default settings after minutes of recording | 3–4 cameras over 40 m fiber HDMI | Unresolved; power draw suspectedUnresolved | Forum t=155760 |
| 2022-02-09 | Mini Extreme | Not stated | Settings or labels lost | Random settings reset on power loss | Not stated | Not statedNot stated | Forum t=155082 |
| 2022-01-10 | ATEM Mini Pro ISO | Not stated | Reboot or boot hang | Pressing record makes the switcher shut off and reboot; at a job it passed four test recordings, then froze and reset on the real one | Recording to a Samsung T5 2 TB (a Seagate drive did the same) | Recorded in vMix instead. A reply: a Mini Pro freezes when recording to a Samsung driveUnresolved | r/blackmagicdesign |
| 2022-01-08 | Television Studio HD | Not stated | Client-side fault | Companion loses control after ~1.5 h; after a power blip, the Pi and ATEM Software Control can't both connect | Companion build 3645 | Disable/enable; reboot the switchCame back after recovery | companion-module #168 |
| 2022-01-05 | ATEM Mini Pro (replacement unit) | Not stated | Hardware, power or heat | Switching HDMI out to multiview showed green waves; after a replug only the Mic 1 ON button lit, and computers did not recognise it in recovery mode | Under 20 hours of use, left on for hours showing graphics | Another power supply did not help. A reply in 2023 had the sameUnresolved | r/blackmagicdesign |
| 2021-12-30 | Mini Extreme ISO | Not stated | Firmware update failure | MIC1 flashing 5+ min; Setup can't see it | Tried a "factory reset" | Not statedNot stated | Forum t=153018 |
| 2021-12-13 | Television Studio HD | 8.6.4 | Settings or labels lost | Still broken | User has 6 units | Not statedNot stated | Forum t=110658 |
| 2021-12-12 | Constellation 8K | 8.6.3 | Reboot or boot hang | Less than six months old: boots halfway and locks up. The 8.6.4 update reported success, but it would not boot | The morning of a Christmas service | Back on 8.6.3 it was unstable with vertical lines on the multiview; a second factory restore with 8.6.3 left it stable enough to broadcastCame back after recovery | r/blackmagicdesignr/VIDEOENGINEERING |
| 2021-12-07 | Mini Extreme ISO | ATEM Software Control 8.6.4 | Media pool or storage | Pool images never load | ATEM Software Control opened after switcher boot | Reopen ATEM Software ControlFixed or improved | Forum t=152034 |
| 2021-12-05 | ATEM Mini Pro | 8.6.1 (ATEM Software Control 8.6 / 8.6.1) | Client-side fault | ATEM Software Control crashes the moment it connects; ATEM Setup still works | Windows 10 | Deleting Documents/ATEM Autosave fixed it but reset the streaming settings. Replies: turning off a VPN; Windows 8 compatibility mode on Windows 11; the same on macOS Sonoma with 9.6.2Fixed or improved | r/blackmagicdesign |
| 2021-11-15 | Television Studio Pro 4K | Not stated | Reboot or boot hang | Shuts off at random mid-service, weekly | Light load, not hot | PSU suspected; try the 12 V XLR inputNot stated | Forum t=150871 |
| 2021-10-26 | 1 M/E (generation not stated) | Not stated | Ethernet dead | No link lights to any switch or control surface, but works cabled straight to a computer | Cables swapped | Not statedNot stated | r/blackmagicdesign |
| 2021-08-01 | Mini Extreme | Not stated | Reboot or boot hang | Powers on frozen, no output | Switched off at the wall between streams | Full unplug works bestCame back after recovery | Forum p=778802 |
| 2021-08-01 | ATEM Mini Extreme ISO | Not stated | Front panel, recording or video freeze | Three times the record button froze red and would not turn off until the unit was unplugged; the drive then held no files | Recording to a LaCie Rugged 500 GB | A reply reports the same twice with a LaCie 2 TB SSDUnresolved | r/blackmagicdesign |
| 2021-07-15 | Television Studio Pro 4K | Not stated | Settings or labels lost | multiview labels turn to "black" | Power cycle | Fix lasts until next power cycleCame back after recovery | Forum t=144570 |
| 2021-07-11 | Television Studio HD | latest then | Settings or labels lost | multiview labels reset except input 8 | Reboot | Not statedNot stated | Forum t=144353 |
| 2021-06-29 | ATEM Mini | ATEM Software Control 8.6.1 | Client-side fault | Has problems at times; every power cycle of the switcher crashes the connected Mac | macOS Big Sur; through a USB hub and also direct | Unplugging power for 10 s and restoring settings usually helpsCame back after recovery | r/blackmagicdesign |
| 2021-06-20 | Not stated (in an ATEM Mini thread) | Not stated | Output or audio failure | Output froze over and over in one day, after a year without problems or changes | Not stated | Unplugged the switcher each timeCame back after recovery | r/blackmagicdesign |
| 2021-06-06 | Mini Extreme | Not stated | Settings or labels lost | Settings lost at switch-off; XML misses keys | Not stated | Not statedNot stated | Forum t=141775 |
| 2021-05-20 | Not stated | Not stated | Control lockout | Only 4 of 10 tallies connect | 10 DIY Wi-Fi tallies | Tally-server modeFixed or improved | ESP tally #44 |
| 2021-05-12 | Television Studio HD (2 units) | 8.6.1 | Settings or labels lost | Media, mixer, labels lost; PGM/PVW, IP, mode, macros kept | Not stated | Clear + recovery reflash no help; 7.x fixedFixed or improved | Forum t=110658 |
| 2021-05-09 | ATEM Mini Pro | current then | Output or audio failure | USB feed stays blank in every app until the switcher restarts | Joining Zoom breakout rooms | Another user's replacement unit did the same with a new cable and computer (2021-10); still reported in 2021-12Unresolved | r/blackmagicdesign |
| 2021-04-29 | Mini Pro | Not stated | Media pool or storage | Stopped keeping its still | After a software update | Not statedNot stated | Forum t=104684 |
| 2021-04-13 | Television Studio HD | 8.5.3 | Settings or labels lost | Startup state back to default | Started weeks ago, nothing changed | Not statedNot stated | Forum t=110658 |
| 2021-03-23 | ATEM Mini | Not stated | Output or audio failure | Output into OBS freezes about 2 minutes in | Not stated | Fixed by an update of the computerFixed or improved | r/blackmagicdesign |
| 2021-01-31 | 2 M/E (Production Studio 4K class) | 8.5.3 | Control lockout | All clients lost after 2 h; video ran; ATEM Software Control asks for a firmware update | 4–6 clients incl. Companion, Camera Control Panel, tally | Power cycle failed; re-flashing 8.5.3 fixed itFixed or improved | Forum t=133171 |
| 2021-01-31 | Mini Pro | 8.5.3 | Media pool or storage | Stills seemed lost, came back later | Extra power cycle after update? | Not statedNot stated | Forum t=104684 |
| 2021-01-14 | Mini Pro | 8.5.2 | Media pool or storage | XML restore empties the pool but says "completed" | Not stated | Not statedNot stated | Forum t=131735 |
| 2020-12-17 | Television Studio HD | 8.1.1 to 7.5.2 | Firmware update failure | Ethernet downgrade failed at ~70%; froze | Over Ethernet | Power pull, then finish over USBFixed or improved | Forum t=110658 |
| 2020-12-12 | Mini Pro ISO | 8.5.3 | Media pool or storage | Pool empty after power cycle | Earlier update hadn't really applied | Forced USB updateFixed or improved | Forum t=104684 |
| 2020-11-29 | Television Studio HD | Not stated | Output or audio failure | Twice in rehearsal the XLR inputs turned to white noise and the headphone output stopped; the analog audio section stopped while camera audio continued | The poster ties it to clipped input signals | A power cycle restored itCame back after recovery | r/VIDEOENGINEERING |
| 2020-11-09 | ATEM Mini Pro | Not stated | Settings or labels lost | After every power cycle the mic pans: about 32 samples of delay between left and right. Touching the delay control clears it until the next reboot | A 2-frame audio delay on mic 1 saved in the startup state | Blackmagic support was looking into itCame back after recovery | r/blackmagicdesignr/blackmagicdesign |
| 2020-11-01 | ATEM Mini Pro ISO | 8.5.1 or 8.5.2 | Reboot or boot hang | Reset itself twice in 10 minutes while streaming | Recently updated firmware; warm, not hot; vents clear; power plug screwed in | The poster planned a downgradeNot stated | r/blackmagicdesign |
| 2020-10-20 | Constellation 8K | 8.1.2 (sw 8.5) | Front panel, recording or video freeze | Cascade: panel drops, then PC, then multiview VU meters stutter, then front buttons die; video runs | Companion, Stream Decks, 4 media players, macros; isolated LAN; warm, not hot | Unplug; Blackmagic says "update everything"Came back after recovery | Forum t=123840 |
| 2020-10-01 | Older 2 M/E (the title says 1 M/E) | Not stated | Firmware update failure | A USB firmware update crashed the laptop at the same point every time, on two laptops and cables; afterwards no multiview and the unit runs cool | Firmware update over USB from a MacBook Pro | Not statedUnresolved | r/blackmagicdesign |
| 2020-09-29 | Mini Pro | Not stated | Control lockout | Earlier clients can't reconnect; ATEM still visible | Several ATEM Software Control over LAN + Wi-Fi | Fewer clientsFixed or improved | Forum t=122610 |
| 2020-09-10 | Not stated (in an ATEM Mini Pro ISO thread) | Not stated | Front panel, recording or video freeze | After 64 minutes recording and streaming stopped; the record and stream buttons did not respond while cuts still worked | ISO recording to a Samsung T5 2 TB plus a YouTube stream | Not statedNot stated | r/blackmagicdesign |
| 2020-08-30 | ATEM Mini Pro ISO | Not stated | Front panel, recording or video freeze | At minute 32 of a livestream everything crashed and the unit did not respond; after a reboot it crashed again | ISO recording to an external SSD rated 533 MB/s | Stable after ISO recording was dropped, but all settings and stills had reset and were rebuilt liveFixed or improved | r/blackmagicdesign |
| 2020-08-18 | ATEM Mini Pro | Not stated | Output or audio failure | USB video goes black while audio keeps working | A Teams or WebEx call starting | Fixed by a power cycleCame back after recovery | r/blackmagicdesign |
| 2020-07-24 | Television Studio HD (+ Television Studio Pro 4K 2023) | 7.5.2; 9.2.2 / 8.6.5 / 7.5.2 | Firmware update failure | Won't boot; "invalid state"; solid red SET | Interrupted update | Mixed; some USB reinstalls workedNot stated | Forum t=118314 |
| 2020-07-21 | Mini Pro (+ Mini Extreme 2021) | 8.3 / 8.6 | Firmware update failure | Fails at 70%; random recovery-mode boots; "EEPROM?" | Not stated | Support; another PC saw "Blackmagic USB restore"Not stated | Forum t=118116 |
| 2020-07-19 | Mini Pro (+ Pro ISO) | Not stated | Front panel, recording or video freeze | Stream stops; ON AIR dead; 30 min–1.5 h in | Church streams; heat and HDMI source suspected | Power cycleCame back after recovery | Forum p=669565 |
| 2020-07-11 | ATEM Mini | Not stated | Output or audio failure | USB webcam picture goes black, three or four times in one event | Joining Zoom breakout rooms (2018 MacBook Pro) | Rebooted the switcher and restored a backup fileCame back after recovery | r/blackmagicdesign |
| 2020-07-07 | ATEM Mini Pro | Not stated | Output or audio failure | USB webcam picture goes black at random, two or three times within a few minutes | Zoom on a MacBook Pro | Power-cycling the switcher was the only fixCame back after recovery | r/blackmagicdesign |
| 2020-06-20 | 2 M/E (generation not stated) | Not stated | Front panel, recording or video freeze | Froze once; another time the audio section stopped outputting audio | Running 24/7 for over three years on a UPS | A restart both timesCame back after recovery | r/VIDEOENGINEERING |
| 2020-06-17 | "larger ATEMs" | 8.2.1 and later | Settings or labels lost | Blackmagic (relayed): bug in label and media file saving | Not stated | Roll back to 8.1.0Not stated | Forum t=110658 |
| 2020-05-20 | Not stated (in an ATEM Mini thread) | Not stated | Media pool or storage | Restoring saved settings brings stills back only on the ATEM Software Control install that added them, with the files at the same paths; stills added from a second computer do not come back | Two computers running ATEM Software Control | Settings restored or rebuiltUnresolved | r/blackmagicdesign |
| 2020-05-10 | Television Studio HD | Not stated | Client-side fault | Client reconnect loop ("missed 3 pings") | Blocked Node event loop | Library fixFixed or improved | atem-connection #82 |
| 2020-04-21 | ATEM Mini | Not stated | Media pool or storage | Saving the startup state keeps the chroma key and audio levels, but not the images | Power cycle | A reply relayed Blackmagic support: image storage is volatile; save and restore insteadExpected or not a switcher fault | r/blackmagicdesign |
| 2020-04-18 | Television Studio HD | 8.2.1 | Settings or labels lost | Labels revert; new media lost, old media survives | After the update | 7.5.2 worksFixed or improved | Forum t=110658 |
| 2020-04-11 | Television Studio HD | Not stated | Firmware update failure | "Update failed"; frozen 20 min; fans full, SET red | Not stated | USB recovery with ATEM SetupFixed or improved | Forum t=111134 |
| 2020-04-05 | Television Studio HD | 8.1.2 | Settings or labels lost | Save Startup State doesn't work | After 7.2 to 8.1.2 | Restore XML every bootCame back after recovery | Forum t=110658 |
| 2020-02-04 | Television Studio HD | Not stated | Hardware, power or heat | Dead after a power outage; no lights | Car hit a power pole | Internal PSU dead; ran on 12 V XLR; others repaired twiceFixed or improved | Forum t=107020 |
| 2020-02-01 | Mini | 8.1 / 8.1.1 | Firmware update failure | Stuck at "update required"; fails at 85% or 70% | 3 cables, 3 PCs | RMA or exchange; one fixed after 24 h in update modeFixed or improved | Forum t=106841 |
| 2020-01-31 | ATEM Mini | Not stated | Media pool or storage | Stills in the media pool are gone after every power cycle | Power cycle | Replies: the media pool is held in RAM on these models, so it is saved and restored insteadExpected or not a switcher fault | r/blackmagicdesignr/VIDEOENGINEERING |
| 2020-01-28 | 2 M/E Production Studio 4K | Not stated | Settings or labels lost | Phantom 2nd M/E; XML restore no effect; Clear Startup State fails | Imported macros from a Television Studio 4K | Not statedNot stated | Forum t=106598 |
| 2019-11-02 | Television Studio HD | before 8.x | Control lockout | Session slots run out; only a restart frees them | Wi-Fi tallies roaming between APs + 3 clients | Tally with one shared sessionFixed or improved | Forum t=101841 |
| 2019-10-08 | Production Studio 4K | 8.0.1 | Control lockout | ATEM Software Control can't connect after the atem-connection library did | Custom Node app | Restart ATEM; maintainer doesn't know whyCame back after recovery | atem-connection #61 |
| 2019-07-02 | Constellation 8K | 8.0.1 | Front panel, recording or video freeze | "Freezes the Atem" | After the update | 8.0 partly worked; unit replacedNot stated | Forum t=94114 |
| 2019-05-29 | 2 M/E Production Studio 4K | Not stated | Media pool or storage | Pool erased on power loss | Volatile by design | Script re-uploads at bootExpected or not a switcher fault | Forum t=92211 |
| 2019-04-21 | 1 M/E Production Studio 4K | 7.5.2 | Control lockout | All connections drop for a few seconds | ~3 clients on a church LAN | Isolate the networkCame back after recovery | Forum t=89893 |
| 2019-02 to 2021 | Television Studio 8.1, Mini Pro 8.5.2, Studio 4K 8.0.1 | as listed | Media pool or storage | ATEM Software Control crashes importing media | PC-specific; also a bug when resolution changed after the first upload | Not statedNot stated | Forum t=85919 |
| 2018-09-10 | 1 M/E Production Studio 4K | Not stated | Hardware, power or heat | Would not power on unless the power cable was unplugged and replugged several times | Not stated | Returned to Blackmagic under RMANot stated | r/VIDEOENGINEERING |
| 2018-05-30 | Not stated (with a hardware panel) | Not stated | Control lockout | The panel connected for about 5 minutes, then disconnected, over and over | All devices on 168.x.x.x addresses, a publicly routable range | Stable after moving everything to 192.168.x.xFixed or improved | r/VIDEOENGINEERING |
| 2018-02-20, 2020-01 | 1 M/E Production Switcher; 1 M/E HD | Not stated | Firmware update failure | Update loop; BSOD mid-update left PSU LED off; multiview dead | Windows crash mid-update | Feared brickedUnresolved | Forum p=588682 |
| 2018-01-09 | 2 M/E Broadcast Studio 4K | 7.2 | Control lockout | Panels + PC drop at the same time 3 Sundays running | 6 clients incl. Wi-Fi iPad and iPods; "new since 7.2" | Power cycle; Blackmagic blames Wi-Fi; still seen in 2021 with no Wi-FiCame back after recovery | Forum p=384298 |
| 2017-12-18 | 1 M/E Production Studio 4K (two units) | Not stated | Hardware, power or heat | The second of two units started to die; the first had died two months earlier | Live-event use for two years | A reply moved from an ATEM 4K to another brand over similar SDI failuresNot stated | r/VIDEOENGINEERING |
| 2017-03-08 | Television Studio HD | 7.0 | Firmware update failure | Repeated failures; fans full, SET flashing red | Faulty USB cable | New cable; "don't update over LAN"Fixed or improved | Forum t=57086 |
| 2015-11-18 | 2 M/E Production Studio 4K | 6.6.1 | Media pool or storage | 31-frame stinger takes 94 s to upload | Every ATEM Software Control instance downloads every upload | Keep one ATEM Software Control connectedFixed or improved | Forum t=41902 |
| 2015-11-01 | 1 M/E 4K + Broadcast Panel | 6.5 | Settings or labels lost | Panel labels vanish | Intermittent | Panel power cycleCame back after recovery | Forum t=41371 |
| 2015-06-21 | 1 M/E Production Studio 4K + old 1 M/E | Not stated | Control lockout | PC and panel locked out; still answers ping | ATEM Software Control + panel on a 10/100 switch; reconnects use up slots | Power cycle; one user went back to 6.3Came back after recovery | Forum t=36664 |
| 2015-02-14 | 1 M/E | 6.3 | Settings or labels lost | Labels and multiview layout reset; macros not saved | Autosave on; Save Startup State used | 6.2 fixed it; 6.3 broke it againFixed or improved | Forum t=32529 |
| 2015-02-12 | 2 M/E Production Studio 4K | latest then | Control lockout | Two PCs can't connect next morning | Left on overnight | Not statedNot stated | Forum p=32140 |
| 2014-10-07 | 2 M/E | Not stated | Settings or labels lost | Total factory reset at power-on | No cause found | Not statedNot stated | Forum t=28137 |
| 2014-08 | 1 M/E (3 units) | Not stated | Settings or labels lost | All back to factory settings | Weekend power outage | Not statedNot stated | Forum t=28137 |
| 2014-02-17 | 1 M/E Production Studio 4K (2 units) | Not stated | Hardware, power or heat | One dead on arrival; one dead after a week; fuse OK | Dealer saw failures on power cycling | RMANot stated | Forum t=19070 |
| mid-2014 | 1 M/E | Not stated | Settings or labels lost | Full reset incl. IP and video mode (1080i50 to 1080i59.94) | Found on site; flat battery suspected | Reset over USB; never againFixed or improved | Forum t=28137 |
| 2013-12-19 | Television Studio (original) | 2013 software | Settings or labels lost | No startup state; config lost | Power failure | Model had no save thenNot stated | Forum t=16673 |
| 2013-06-22 | Television Studio | software ~4.0 | Media pool or storage | Adding media throws ATEM Software Control back to the IP dialog | One laptop only | Build 4.1Fixed or improved | Forum t=9315 |
| 2013-03-13 | 1 M/E and Television Studio | Not stated | Control lockout | Locked out mid-show, no cuts | ATEM Software Control + Broadcast Panel; Wi-Fi router on LAN | Not statedNot stated | Forum p=32140 |
| 2013-03-13 | ATEM (model unclear) | Not stated | Ethernet dead | Ethernet dead, no port LEDs | Mac mini via Cisco switch; iPhone app on Wi-Fi | Many power cycles; comes back, fails againCame back after recovery | Forum p=32140 |
| 2013-02-19 | 1 M/E (2 units) | software 3.5 | Control lockout | Stops switching after 20 h to days; still sends packets; ATEM Software Control can't connect | Custom client connects and disconnects every 4 s | Restart; keep one sessionCame back after recovery | Forum t=4436 |
| 2013-02-18 | Television Studio | software 3.3 / 3.4 | Control lockout | No reconnect after a few connection losses | Win7 wired; wired + Wi-Fi Macs | RestartCame back after recovery | Forum p=32140 |
| 2013-02-15 | Television Studio | software 3.3–3.4 | Control lockout | No client connects. Answers ping and UDP hello, never sends state | 30–40 client restarts; Wi-Fi retries | Power cycle onlyCame back after recovery | Forum p=32140 |
| undated | various | Not stated | Media pool or storage | Switcher needs a restart; no button pushes work | Image not at the exact video-mode size | RestartCame back after recovery | MixEffect docs |
| undated | various (WebATEM) | Not stated | Media pool or storage | Previews spin until switcher reset | Media pool lock held by a stuck app | ResetCame back after recovery | WebATEM PR #51 |
| older | Television Studio (original) | Not stated | Hardware, power or heat | Wall adapter overheats; unit stops after 15–20 min | 30 W adapter | Bigger adapter (search summary only)Fixed or improved | Forum t=2088 |
| undated | Not stated | Not stated | Client-side fault | Transition freezes halfway if preview changes during Auto | "ATEM feature" | Won't fixExpected or not a switcher fault | companion #392 |
| undated | Not stated | Not stated | Client-side fault | Companion module fails at startup | Too much sent to the module at once | Companion-sideNot stated | companion #3667 |