Connection troubleshooting
| Symptom | Start with |
|---|---|
| RCP page does not load | Address, port, app/service and firewall. |
| RCP is offline | The selected production's Core. |
| One module disconnected | Its Run on, address/device and module settings. |
| Discovered device absent from Camera Control | Assignment and camera head in Visual Setup. |
| Controls work, no picture | Video troubleshooting. |
| Local access works, Cloud fails | Account access, Core Cloud status and build compatibility. |
| Panel controls the wrong camera | Controller switcher group and selector mapping. |
| One camera control is greyed out | Head/accessory support for that control. |
Browser cannot reach RCP
- Open RCP locally on its computer to check that the service is running.
- Use its LAN address from other computers.
localhostrefers to the computer running the browser. - Use the configured port: normally HTTP 5994 or desktop HTTPS 2997.
- Check the OS firewall and the network path between client and host.
Browser USB, serial and Bluetooth require HTTPS on a LAN address.
Browser support missing
If a feature asks to install browser support, open Setup → About & Updates on the RCP computer providing that service. Choose Download browser support, then Download and restart. RCP saves the production and restarts.
Hardware module disconnected
- Open Setup → Equipment or select the module in Visual Setup.
- Read its status and error.
- Check Run on. The device must be reachable from that computer.
- Check address, port, protocol/model and authentication.
- For USB/serial, check device permissions and whether another application holds the device.
If ping succeeds but the module still cannot connect, check that the device's remote-control service is enabled and its credentials match the module settings.
Device not discovered
Open Setup → Device Discovery and inspect the relevant service. Check that the selected network interface reaches the device's network. Discovery broadcasts and multicast may not cross routers or VLANs.
Where supported, enter the device's address manually.
Reveal in Visual Setup opens an existing module or the device's Add nodes entry. See Device discovery to add it to the production.
Satellite unavailable
Open RCP Instances to check whether the Satellite can reach Core. Its local page can still load when that connection is down, so a working page alone does not confirm that it has joined the production.
For a local connection, check Core's saved address and port from the Satellite computer. For a Cloud connection, check that both computers are signed in to the same organization and production. Follow any compatibility or membership error shown in RCP Instances.
If the Satellite is connected but its equipment is missing, inspect Run on or Capture on and the device attachment on that computer.
Cloud access fails
If local control works:
- Check the account's organization/production access or Cloud-link expiry.
- Check Core's internet connection and clock.
- On Core, open Setup → About & Updates → Cloud access and choose Check cloud access now.
- Follow any update or compatibility message shown there.
See Cloud control.
Connection lost after an address change
Setup → Network changes the selected RCP computer's network settings. Changing its address can disconnect browsers and Satellite links. Reconnect using the new address, or use the computer's local interface to correct it.
For unresolved faults, send a report with the error, affected module/instance and time.