Panasonic panels
Choose the module according to whether the panel should send camera commands through RCP or whether RCP should follow the panel's camera selection:
| Module | Direction and purpose |
|---|---|
| Panasonic PTZ/ROP Panel Control Input | The panel sends camera commands to a listener supplied by Multicam RCP |
| Panasonic Panel Camera Selection | Multicam RCP reads/changes which camera the actual panel has selected |
Receive camera controls
- Attach Panasonic PTZ/ROP Panel Control Input to the camera's controller stack.
- For network control, set the listening Port (
81by default), then point the panel's camera entry at that host and port. - For serial control, choose the serial transport, Run on and Connection device and matching Baud Rate (
9600by default), or configure the serial bridge.
Follow the panel's camera selection
- Add Panasonic Panel Camera Selection in Visual Setup.
- Enter the panel's IP Address and Port (
80by default). - Select Panel Model and set Number of inputs. Profiles cover AW-RP50/RP60/RP120/RP150/RP200.
- Attach the selector to the camera controller switcher's selected-camera stack and map its camera numbers to groups.
To make a monitor/AUX follow selection, link the controller switcher's selected-camera output to a configured monitoring route.
For RP50 camera assignment and RP150 configuration files, use Production Toolbox.