Skip to main content

VISCA, Sony FR7 and OBSBOT

Use VISCA Protocol PTZ Camera as the head for a camera controlled through VISCA. Its model setting selects the command set, including the additional HTTP controls used by Sony FR7 and OBSBOT Tail 2. To connect a hardware panel that sends VISCA commands into RCP, use VISCA PTZ Panel.

VISCA connection setup​

  1. Check whether the camera uses network VISCA or a serial control port, then attach VISCA Protocol PTZ Camera in Visual Setup.
  2. Select the actual Device Model. Use the manufacturer-specific guide below for model differences.
  3. For network control, enable VISCA over IP on the camera and enter its IP Address, Port and matching Protocol Type. Framed Sony VISCA normally uses UDP port 52381.
  4. For serial control, select Serial port (RS-232/422), Run on and Connection device, then match Baud Rate and Camera ID to the camera.
  5. Match System Frequency and verify a slow movement and stop before operating.

Generic VISCA over IP​

  1. Enable VISCA network control on the camera.
  2. Add a camera and attach VISCA Protocol PTZ Camera in Visual Setup.
  3. Choose the actual Device Model, or generic VISCA if there is no matching profile.
  4. Set the address, port, protocol and camera ID to match the device.
  5. Test slow pan/tilt, neutral stop, zoom and a spare preset.
SettingDefaultMeaning
TransportNetworkUDP camera control; serial is a separate choice
Port52381Replace if the camera specifies another port
Protocol TypeVISCA-over-IPFramed VISCA-over-IP differs from raw VISCA over UDP
Camera ID1Addressed camera, especially important on serial chains
System FrequencyPALMatch video frequency for model-dependent shutter choices
Run onRCP CoreComputer or supported device that connects to the camera

Profiles include AIDA PTZ4K12G FNDI X30, BirdDog P200 A4, Bolin N2-220X, JVC, Minrray, NewTek, PTZOptics, SMTAV and ValueHD VX60/VX90 families.

VISCA over IP connection settings.
VISCA PTZ settings in Visual Setup
VISCA PTZ settings in Visual Setup

VISCA over IP connection settings.

Serial VISCA​

Choose a serial transport, location, device and baud rate (9600 default; some heads use 38400). For a network serial bridge, configure its remote/listening address.

Match the camera's RS-232 or RS-422 wiring and camera address.

Sony BRC and SRG model selection​

Use the exact Device Model, or Sony BRC/SRG (detect model) when the camera's identity can be read. Do not assume every BRC/SRG body has Ethernet VISCA: for serial-only hardware, follow the serial procedure above. Network-capable Sony VISCA uses the framed VISCA-over-IP (Sony/PTZOptics) option, normally UDP 52381.

Device ModelConnection notes
Sony BRC-X400/X401Use the network or serial interface documented for this body
Sony SRG-X400/X402/201M2Use the network or serial interface documented for this body
Sony SRG-X120/HD1M2Use the network or serial interface documented for this body
Sony SRG-X40UH/H40UHUse the network or serial interface documented for this body
Sony SRG-A40VISCA plus HTTP for additional controls
Sony SRG-A12VISCA plus HTTP for additional controls
Sony BRC-AM7VISCA plus HTTP for additional controls
Sony BRC-X1000/H800/H780Use the network or serial interface documented for this body
Sony SRG-120DHUse the network or serial interface documented for this body
Sony SRG-300HUse the network or serial interface documented for this body
Sony SRG-360SHE/280SHEUse the network or serial interface documented for this body
Sony ILME-FR7HTTP credentials and VISCA; see below

SRG-A12, SRG-A40 and BRC-AM7 have an additional HTTP control path. Enter Username, Password and HTTP Port (80 default) for their web control account when using those functions. If movement works but an image or tracking adjustment fails, check HTTP access separately. Selecting the profile does not establish hardware validation of every camera function.

For other manufacturers using this module, follow the AVer, Lumens, Marshall, Telycam or Datavideo setup guide.

Sony ILME-FR7​

Select Sony ILME-FR7 so the module uses the camera's authenticated HTTP controls. Focus speed also uses VISCA over IP, so enable that second connection when setting up focus control.

  1. Complete Sony's initial web setup and set the administrator password.
  2. Enter IP Address, HTTP Port (80 default), Username and Password.
  3. For focus speed, enable VISCA over IP: FR7 SETUP switch 3 on, followed by the required camera restart.
  4. Wait for model, firmware and lens information in the module log.
  5. Verify movement/stop, zoom and manual exposure. Test focus speed separately.

Iris and shutter require compatible manual modes. Red/blue white gain requires a suitable memory mode.

FR7 tally uses external tally mode. Check brightness and green-lamp enablement if the camera remains dark. External tally can take over the lamp's normal recording indication; red takes priority when red and green are both requested.

Sony documents the SETUP switch and restart requirement and external tally behavior.

FailureCheck
HTTP 401Credentials and initial camera setup
HTTP 403Camera access/Referer settings and the module's error hint
Focus speed alone failsVISCA enablement, UDP access and restart after SETUP change
Pan/tilt refusedCamera movement lock and mechanical state

OBSBOT Tail 2​

  1. Enable VISCA over IP in OBSBOT settings.
  2. Select OBSBOT Tail 2 as Device Model in VISCA Protocol PTZ Camera.
  3. Enter IP Address, Port 52381, Protocol Type → VISCA-over-IP (Sony/PTZOptics), Camera ID 1 and HTTP Port 80.
  4. Select the connection location that reaches the camera and wait for live settings.

Tail 2 uses VISCA for movement, HTTP for image/tracking controls and WebSocket for feedback. Wait for its live settings before operating it. If access is refused, resolve the camera's ownership/permission settings; the module does not perform OBSBOT account authentication.

ControlTail 2 interpretation
GainISO divided by 100: 1–32 means ISO 100–3200, not dB
IrisExposure compensation +3 to −3 EV, midpoint 0 EV; not physical iris
Absolute zoomRetained scale runs from 12× at one end to 1× at the other
TrackingSupported subject modes, framing, speeds and axis locks
TintImage tone

Tally and OSD are unavailable for Tail 2.

For Tail Air or Tail 2 OSC recording/still/gimbal additions, see OBSBOT OSC setup.