Panasonic PTZ and AW cameras
Panasonic PTZ Camera uses Panasonic's AW control protocol to provide the movement, lens and image controls supported by the connected model. Add it as the camera head and connect over the network or the camera's AW serial interface. For other Panasonic control interfaces, see P2/HC ROP or RC10/EC4 serial.
Network setup
- Enable camera network control and find its address in its setup interface or Setup → Device Discovery.
- In Setup → Visual Setup, add a camera and attach the detected device or Panasonic PTZ Camera as its head.
- Use network Transport, set IP Address, and leave Outbound HTTP Port at
80unless configured differently. - Choose the connection location that can reach the camera; the default uses the server's network.
- Wait for reported values and the detected model in Status.
Inbound TCP Port receives camera notifications. Allow the camera to reach that port on the connection host and use a distinct listener per camera. HTTP polling can work while notifications are blocked, leaving some feedback or auto-balance results incomplete.
Panasonic camcorders
These camcorders take the same AW commands as the PTZ cameras: AG-CX350, AG-CX200, AJ-CX4000, AJ-UPX360 and AJ-UPX900. Use Panasonic PTZ Camera for them, not Panasonic P2 / HC ROP. Device Discovery offers a detected one as Panasonic PTZ Camera.
The AG-CX370 and AJ-UPX380 have no web port: connect them with Panasonic P2 / HC ROP.
- On the camera, open NETWORK and set DEVICE SEL to LAN.
- Set IP REMOTE to ENABLE(HOLD), so remote control stays on after a restart.
- Leave the camera's AUTO/MANUAL switch at AUTO, and close the camera's menu and thumbnail screen while RCP connects.
- Add Panasonic PTZ Camera with the camera's IP Address. The camcorder connects over HTTP port
80and asks for no username or password.
The camcorders have no pan/tilt head. Lens, exposure and paint controls follow what the model supports.
Model-specific behavior
The module uses the camera model to choose commands and ranges for shutter, white balance, pedestal, matrix and output settings. The model is detected from the camera; the list below names the models the AW protocol covers; there is no manual model picker.
AW-UE160: uses its own red/blue gain and pedestal commands. Check the detected model if these controls fail.
AK-UB300: has no pan/tilt head. Wait for automatic white/black balance to complete before adjusting white balance or pedestal. Failures/timeouts appear in the module log.
Models covered
AK-UB300, AW-HE120, AW-HE130, AW-HE145, AW-HE20, AW-HE40, AW-HE42, AW-HE50, AW-HE60, AW-HR140, AW-UB10, AW-UB50, AW-UE100, AW-UE150, AW-UE150A, AW-UE160, AW-UE20, AW-UE4, AW-UE40, AW-UE50, AW-UE70, AW-UE80, AW-UR100, AW-HE35, AW-HE38, AW-HE48, AW-HE58, AW-HE65, AW-HE70, AW-HN38, AW-HN40, AW-HN65, AW-HN70, AW-UE63, AW-UE65, AW-UN70, AW-HE68, AW-HE75, AW-UE155, AW-UN145, AW-HN130, AW-UE30, AW-UE5, AW-HE2, AG-CX350, AJ-UPX360, AG-CX200, AJ-CX4000, AJ-UPX900, AG-UCK20, AG-MDC20, AK-UBX100.
The list includes regional identities and fixed cameras as well as PTZ heads. AK-UB300, AK-UBX100, AW-UB10/AW-UB50 and the AG/AJ camcorders do not have an integrated pan/tilt mechanism. Functions are selected for the detected model and its reported capabilities.
Authentication
This AW module sends HTTP control without a username/password exchange. The camera must permit that control connection. A working browser login alone does not establish that the camera accepts AW commands from RCP.
Follow Panasonic camcorders above for the AG-CX350/CX200 and AJ-CX/UPX models. The newer AG-CX370 and AJ-UPX380 use the account-based P2 / HC ROP connection.
Find the model-specific AW interface reference in Panasonic's control documentation. The CX350 connection note illustrates the remote-enable settings.
Exposure, paint and presets
The camera's operating mode determines whether it accepts a manual adjustment. Set the relevant mode before using the control in RCP:
| Task | Preparation |
|---|---|
| Manual iris | Disable automatic iris, which can override manual values |
| Gain | Check auto-gain mode and the camera's supported range |
| Shutter | Choose the appropriate mode first; step and synchro-scan differ |
| Color temperature | Select a white-balance mode that permits variable temperature |
| Red/blue gain | Use a compatible manual/memory white-balance mode |
| Auto white/black balance | Prepare scene/lens as required, trigger once and wait for the result |
A control returning to its old value often means an automatic mode, rejection or model limitation. Read Status before treating it as a network failure.
Serial AW control
For a camera with an AW serial interface, choose serial Transport, Run on, Connection device and Baud Rate (9600 default). Network serial bridges have separate remote/listen fields.
Match the camera's RS-232 or RS-422 interface and wiring.
Tally and video
Connect the camera to its switcher input in Visual Setup so RCP can follow its program/preview tally. To see its picture in Camera Control or Monitoring, also add a video source and associate it with the camera.
Troubleshooting
An AG-CX350, AG-CX200, AJ-CX4000, AJ-UPX360 or AJ-UPX900 on Panasonic P2 / HC ROP says its login was turned down: it belongs on Panasonic PTZ Camera. Remove the P2 module and add the camcorder as Panasonic PTZ Camera.
A camcorder gets "The connection failed" or "camera unreachable" on port 80: the AG-CX370 and AJ-UPX380 have no web port. Use Panasonic P2 / HC ROP.
Not discovered: enter the address manually after checking reachability from the connection host. Routed networks may pass HTTP while blocking discovery broadcasts.
No movement: check power/standby, control permissions, another operator, limits, and whether the device actually has a PTZ head.
Delayed feedback or missing auto-balance result: check the inbound port/firewall and module log.
One paint control fails: verify model and camera mode. Include the exact control, model, firmware and refusal in a support report.
See Camera panels for Panasonic operator panels.